measurement of anterior–posterior diameter of ivc by ultrasonography: a non invasive method for estimation of central venous pressure.
نویسندگان
چکیده
introduction:the assessment of intravascular volume in severely traumatized patients or patients admitted in icu is very essential. at present the accurate method for estimating the intravascular volume requirement is by measuring the cvp which is an invasive method. the measurement of ivc diameter by ultrasound has been suggested as an easily available and simple method for measuring the intravascular volume status. the purpose of this study was to compare the results of ivc diameter measurement by ultrasonography and cvp measurement for calculating the intravascular volume in icu admitted patients. methods: this was a descriptive and prospective study including 50 patients admitted in icu with a central venous catheter placed for any reason whatsoever and no signs of increased right atrial pressure. cvp was measured in supine position by cvp manometer. the anterior- posterior ivc diameter was assessed by ultrasonography during inspiration and expiration. data analysis was performed by spss and evaluated statistically with pearsons regression and linear correlation test. results: the mean cvp at inspiration and during expiration was 11.35+ 5.53, 12.20 + 5.65 cmh2o, respectively. the mean of inspiratory and expiratory ivc diameter was 7.71 + 3.5 , 11.37 + 3.28 mm, respectively. there was significant correlation between cvp and ivc diameter both during inspiration (r= 0.64 , p-value= 0.001) and expiration (r=0.495 , p-value=0.001) conclusion: the result of this study suggests that ivc diameter measurement by ultrasound can be used as a reliable and non- invasive method for estimating the intravascular volume.
منابع مشابه
study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour
this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...
اندازه گیری قطر قدامی – خلفی ورید اجوف تحتانی توسط سونوگرافی به عنوان یک روش غیر تهاجمی در تخمین میزان فشار ورید مرکزی در بیماران بستری در بخش مراقبت های ویژه
Introduction:The assessment of intravascular volume in severely traumatized patients or patients admitted in ICU is very essential. At present the accurate method for estimating the intravascular volume requirement is by measuring the CVP which is an invasive method. The measurement of IVC diameter by ultrasound has been suggested as an easily available and simple method for measuring the intra...
متن کاملsolution of security constrained unit commitment problem by a new multi-objective optimization method
چکیده-پخش بار بهینه به عنوان یکی از ابزار زیر بنایی برای تحلیل سیستم های قدرت پیچیده ،برای مدت طولانی مورد بررسی قرار گرفته است.پخش بار بهینه توابع هدف یک سیستم قدرت از جمله تابع هزینه سوخت ،آلودگی ،تلفات را بهینه می کند،و هم زمان قیود سیستم قدرت را نیز برآورده می کند.در کلی ترین حالتopf یک مساله بهینه سازی غیر خطی ،غیر محدب،مقیاس بزرگ،و ایستا می باشد که می تواند شامل متغیرهای کنترلی پیوسته و گ...
Predicting Central Venous Pressure by Measuring Femoral Venous Diameter Using Ultrasonography
OBJECTIVES The objective of this exploratory study was to find out the correlation of femoral vein diameter (FVD) to central venous pressure (CVP) measurements and to derive a prediction equation to help ascertain the fluid volume status in a critical patient. PATIENTS AND METHODS This was a single-centered prospective cohort study designed and conducted by the critical care department of Shi...
متن کاملبررسی ارزش تشخیصی میزانCaval index در تعیین فشار ورید مرکزی پایین در مقایسه با روش تهاجمی در بیماران بستری در ICU بیمارستان شهید باهنر کرمان
Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...
متن کاملNon-invasive central venous pressure measurement by compression ultrasound-A step into real life
Information on central venous pressure (CVP) is helpful in clinical situations like cardiac failure and sepsis. Compression ultrasound (CU) of a forearm vein has been shown to be a reliable method for CVP measurement when assessed by experienced personal under study conditions. To test the hypothesis, that CU can be reliably used for CVP measurement after a training program and using a portable...