evaluation of bacterial contamination in anesthesia breathing circuits

نویسندگان

محمدعلی کریمی زارچی

ma karimi-zarchi . karimi _ inv @ yahoo.com فرحناز فرنیا

f farnia

چکیده

introduction : hospital infections are one of the important reasons of mortality and incurred expenses. therefore, we must control these infections by identifying contamination sources. the aim of this study was the determination of bacterial pollution of corrugated anesthesia sets in surgical rooms. methods: this study was an analytic-description one performed in training hospitals of yazd city. research sample was 440 cases provided from different parts of corrugate after completing the anesthesia period by wet sterile swabs and transferred to culture media. on thursday, each week, a sample from different parts of tube after sterilizing with cetrimide solution was obtained. finally, after 24 hours, culture medias were studied for colony growth. results: obtained results indicated that of 440 cases taken samples, 343 cases were without bacterial pollution, 71 cases (19.29%) had bacterial pollution of samples before sterilizing and 26 cases (36.1%) were polluted after tube sterilizing. conclusion: sampling and culturing from used equipment and tools in hospital is one of the important actions for identifying and controlling hospital infections. obtained results from this study indicated that of 440 cases, there were 97 cases of pollution. therefore, it is suggested that anti bacterial filters should be installed before y form piece of tubes in anesthesia machines and disposable corrugated tubes should replace traditional tubes. in addition, it seems necessary that wider investigations should be done.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bacterial contamination of anesthesia machines’ internal breathing-circuit-systems

BACKGROUND Bacterial contamination of anesthesia breathing machines and their potential hazard for pulmonary infection and cross-infection among anesthetized patients has been an infection control issue since the 1950s. Disposable equipment and bacterial filters have been introduced to minimize this risk. However, the machines' internal breathing-circuit-system has been considered to be free of...

متن کامل

Contamination of anesthesia circuits by pathogens.

BACKGROUND AND OBJECTIVES Evaluation of contamination of anesthesia circuits by collecting 56 culture samples from the circular system; previously reprocessed tracheas by disinfection with 1% hypochlorite or 2% glutaraldehyde after being washed in non-sterile water and soap and dried by using compressed air and stored in surgical grade paper; and from other places of the non-reprocessed respira...

متن کامل

evaluation of sadr eminence in safavid period

چکیده: یکی از دوره های مهم تاریخی ایران به لحاظ تأمین استقلال ملی مذهبی و حتی تأثیر آن بر فرهنگ و مذهب ایرانیان، دوره صفویه است. رسمیت دادن و رواج مذهب شیعه توسط شاه اسماعیل اول، یکی از مهمترین اقدامات این دولت محسوب می شود. بنابراین برای اجرای این سیاست، وی منصب صدارت را به عنوان منصبی مذهبی- حکو متی ایجاد کرد .این منصب از دوره ی تیموریان ایجاد شده بود ولی در اواخر این دوره اهمیت بیشتری یافت...

15 صفحه اول

Evaluation of Bacterial Contamination in Clinical Environment of Sari Dental School in 2018

Background and Aim: Bacterial contamination of clinical surfaces of dental units that have been touched or been exposed to patients’ blood or saliva can be a reservoir for infections, leading to cross-contamination. This study aimed to evaluate bacterial contamination in the clinical environment of Sari Dental School in 2018. Materials and Methods: In this cross-sectional (descriptive-analytic...

متن کامل

Evaluation of Bacterial Contamination in Dental Unit Water Lines in Zahedan in 2016-2017

Background & Aim: Due to a constant contact of dentists and patients with water and aerosols generated from the dental units, the quality of dental unit waters is very important. This study aimed to evaluate bacterial contamination of dental unit water lines in Zahedan in 2016-2017. Methods: In this descriptive analytical study, 2304 water samples from four parts of unit including cup filler, ...

متن کامل

Frequency of Bacterial Frequency of Bacterial Contamination in Traditional Ice Cream Produced in Arak, Iran (2011)

Abstract Background and Objective: Ice cream is a suitable environment for microbial growth due to its chemical structure, ingredients, and its increased supply and demand. In the absence of hygienic considerations, it can cause poisoning. This study aimed to determine bacterial contamination in traditional ice cream produced in Arak city in 2011. Material and Methods: The samples (n= 30) were ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
مجله دانشگاه علوم پزشکی شهید صدوقی یزد

جلد ۱۵، شماره ۲، صفحات ۱۵-۲۱

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023