pulse oximeter oxygen saturation in prediction of arterial oxygen saturation in liver transplant candidates

نویسندگان

seiyed mohammad ali ghayumi department of internal medicine, shiraz university of medical sciences, shiraz, ir iran

abolfazl khalafi-nezhad department of internal medicine, shiraz university of medical sciences, shiraz, ir iran; corresponding author: abolfazl khalafi-nezhad, department of internal medicine, shiraz university of medical sciences, shiraz, ir iran. tel: +98-7116474316, fax: +98-7116474316, e-mail:

zahra jowkar department of operative dentistry, school of dentistry, shiraz university of medical sciences, shiraz, ir iran

چکیده

results roc-derived spo2 threshold of ≤ 94% can predict hypoxemia (pao2 < 60 mmhg) with a sensitivity of 100% and a specificity of 95%. furthermore, there are associations between the roc-derived spo2 threshold of ≤ 97% and detection of hypoxemia (pao2 < 70 mmhg) with a sensitivity of 100% and a specificity of 46%. the accuracy of pulse oximetry was not affected by the severity of liver disease in detection of hypoxemia. objectives the aim of this study was to evaluate the efficacy of pulse oximetry as a screening tool in hypoxemia detection in liver transplant candidates and to compare the results with abgs. patients and methods three hundred and ninety transplant candidates (237 males and 153 females) participated in this study. arterial blood gas oxyhemoglobin saturation (sao2) was recorded and compared with pulse oximetry oxyhemoglobin saturation (spo2) results for each participants. the area under the curve (auc) of receiver operating characteristic (roc) curves was calculated by means of nonparametric methods to evaluate the efficacy of pulse oximetry to detect hypoxemia. background liver transplant is the only definitive treatment for many patients with end stage liver disease. presence and severity of preoperative pulmonary disease directly affect the rate of postoperative complications of the liver transplantation. arterial blood gas (abg) measurement, performed in many transplant centers, is considered as a traditional method to diagnose hypoxemia. because abg measurement is invasive and painful, pulse oximetry, a bedside, noninvasive and inexpensive technique, has been recommended as an alternative source for the abg measurement. conclusions provided that spo2 is equal to or greater than 94%, attained from pulse oximetry can be used as a reliable and accurate substitute for the abg measurements to evaluate hypoxemia in patients with end stage liver disease.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse Oximeter Oxygen Saturation in Prediction of Arterial Oxygen Saturation in Liver Transplant Candidates

BACKGROUND Liver transplant is the only definitive treatment for many patients with end stage liver disease. Presence and severity of preoperative pulmonary disease directly affect the rate of postoperative complications of the liver transplantation. Arterial blood gas (ABG) measurement, performed in many transplant centers, is considered as a traditional method to diagnose hypoxemia. Because A...

متن کامل

Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation?

INTRODUCTION This study investigates the relation between changes in pulse oximeter oxygen saturation (SpO2) and changes in arterial oxygen saturation (SaO2) in the critically ill, and the effects of acidosis and anaemia on precision of using pulse oximetry to predict SaO2. PATIENTS AND METHODS Forty-one consecutive patients were recruited from a nine-bed general intensive care unit into a 2-...

متن کامل

Zero Oxygen Saturation in Pulse Oximeter: Need for Clinical Correlation

Sir, I would like to share an unusual incident, which had happened recently in our operation theater. This event had occurred while conducting spinal anesthesia for a 28-year-male patient with an inguinal hernia for meshplasty. His preoperative anesthetic evaluation and investigations were unremarkable. In the operating room, the blood pressure (BP) cuff and pulse oximeter were applied in the s...

متن کامل

Cerebral arterial oxygen saturation measurements using a fiber-optic pulse oximeter.

BACKGROUND A pilot investigation was undertaken to assess the performance of a novel fiber-optic cerebral pulse oximetry system. A fiber-optic probe designed to pass through the lumen of a cranial bolt of the type used to make intracranial pressure measurements was used to obtain optical reflectance signals directly from brain tissue. METHODS Short-duration measurements were made in six patie...

متن کامل

A new fibre optic pulse oximeter probe for monitoring splanchnic organ arterial blood oxygen saturation

A new, continuous method of monitoring splanchnic organ oxygen saturation (SpO(2)) would make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischaemia, and, ultimately, death. In an attempt to provide such a device, a new fibre optic based reflectance pulse oximeter probe and processing system were developed followed by an in vivo evalu...

متن کامل

Pulse Oximetry Overestimates Oxygen Saturation in COPD.

BACKGROUND Measurement of oxygen saturation with a handheld pulse oximeter is widely practiced as a surrogate to invasive arterial blood gas analysis. Oxygen saturation is an important parameter in cases of COPD, but there are insufficient data on the role of pulse oximetry in patients with COPD, moreso in diseases across its spectrum, such as chronic bronchitis and emphysema. We assessed the p...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
hepatitis monthly

جلد ۱۴، شماره ۴، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023