ascitic fluid to serum bilirubin ratio for differentiation of exudates from transudates

نویسندگان

amir hossein boghratian hazrat-e-rasool hospital (internal ward. gi section),سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (iran university of medical sciences)

majid chalian iran university of medical sciences, tehran, iran.سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (iran university of medical sciences)

hamid chalian tehran university of medical sciences, tehran, iran.سازمان اصلی تایید شده: دانشگاه علوم پزشکی تهران (tehran university of medical sciences)

yaser ghavami iran university of medical sciences, tehran, iran.سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (iran university of medical sciences)

چکیده

abstract background: regarding the diagnostic errors of the classic criteria including serum ascites albumin gradient (saag), total protein concentration and the adapted light et al’s criteria in distinguishing transudate versus exudates, we evaluated the ascitic fluid to serum bilirubin ratio as a new criteria in this regard. we also evaluated whether the combination of bilirubin ratio with each of these classic criteria improves the diagnostic accuracy.   methods: one-hundred ascitic fluid specimens were analysed prospectively whereas the category of fluid was assessed according to the clinical diagnosis. sensitivity, specificity, positive predictive value (ppv), negative predictive value (npv), overall accuracy, positive likelihood ratio (lr+), negative likelihood ratio (lr-) and the youden’s index of each criterion alone and in combination with the bilirubin ratio were calculated. results: saag seems to be the best criterion (specificity = 0.9090, ppv = 0.97, lr+ = 8.03, youden’s index = 0.64). bilirubin and ldh ratio criteria had equivalent specificity (0.8333 and 0.8205, respectively), accuracy (0.80 and 0.81, respectively), ppv (0.54 and 0.55, respectively), npv (0.90 and 0.93, respectively) and lr+ (4.09 and 4.30, respectively) which generally were better than fluid total protein and total protein ratio but not as predictive as saag. the addition of bilirubin ratio to any criterion did not make any improvement. conclusion: ascitic fluid to serum bilirubin ratio, although not more predictive than saag, can be used as an alternative criterion in distinguishing exudative versus transudative ascitic fluid as it is more cost-effective in terms of laboratory processing and also more available.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ascitic fluid to serum bilirubin ratio for differentiation of exudates from transudates

  Abstract   Background: Regarding the diagnostic errors of the classic criteria including serum ascites   albumin gradient (SAAG), total protein concentration and the adapted Light et al’s criteria   in distinguishing transudate versus exudates, we evaluated the ascitic fluid to serum   bilirubin ratio as a new criteria in this regard. We also evaluated whether the combination of   bilirubin r...

متن کامل

Ascitic fluid to serum bilirubin ratio for differentiation of exudates from transudates

Background: Regarding the diagnostic errors of the classic criteria including serum ascites albumin gradient (SAAG), total protein concentration and the adapted Light et al’s criteria in distinguishing transudate versus exudates, we evaluated the ascitic fluid to serum bilirubin ratio as a new criteria in this regard. We also evaluated whether the combination of bilirubin ratio with each of the...

متن کامل

Pleural fluid to serum bilirubin concentration ratio for the separation of transudates from exudates.

Whether fluid accumulating in the pleural space is a transudate or an exudate is determined by the widely used criteria of the pleural fluid to serum LDH and protein concentration ratios. Such a distinction is important for limiting the extent of the differential diagnosis of possible causes for this condition. We have found that a pleural fluid to serum total bilirubin ratio can serve the same...

متن کامل

Pleural fluid to serum cholinesterase ratio for the separation of transudates and exudates.

STUDY OBJECTIVE To evaluate the usefulness of two new parameters for separating pleural transudates and exudates: pleural fluid cholinesterase level and pleural fluid to serum cholinesterase ratio, and to compare the results with the other well-established criteria. DESIGN Prospective evaluation of the patients referred for diagnostic thoracentesis. SETTING Pulmonary sections of a community...

متن کامل

Separating Exudates From Transudates

Objectives: To evaluate the usefulness of diverse combinations of pleural cholesterol concentration, pleural or serum protein, and lactate dehydrogenase (LDH) levels for the differentiation ofpleural exudates and transudates. Design: Prospective laboratory study of pleural effu¬ sions. Setting: Medical school hospital. Patients: One hundred eighty consecutive internal medicine ward patients in ...

متن کامل

New criteria for the differentiation between transudates and exudates.

AIMS To investigate whether cholesterol and lactate dehydrogenase (LDH) measurements in fluids are more sensitive and specific markers for differentiating between exudates and transudates, as confirmed clinically, than the measurement of fluid total protein concentrations alone. PATIENTS/METHODS Serum, pleural fluid, and ascitic fluid from 61 unselected patients were analysed retrospectively ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
medical journal of islamic republic of iran

جلد ۲۲، شماره ۳، صفحات ۱۳۲-۱۳۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023