assessment of the treatment outcome of closed extra-articular distal tibia fracture: im nailing vs plating
نویسندگان
چکیده
abstract background: the tibial diaphyseal fractures are the most common type of long bone fractures encountered by most orthopedic surgeons. in accordance with descriptive indices of tibia fractures on the basis of their location in the bone, distal tibia fractures have the second incidence of all tibia fractures after the middle tibia fractures. the purpose of the study was to assess the complications and treatment outcome of closed extra-articular distal tibia fracture. methods: the results of the management for 76 patients with closed extra-articular distal tibia fracture by intramedullary nailing and plating were reviewed retrospectively. the variables included ao (arbeitsgemeinschaft fur osteosynthesefragen) classification of tibia fracture, the mean duration of :::::union:::::, mal:::::union:::::, and non:::::union:::::. results: twenty seven and forty nine patients were treated by intramedullary (im) nailing and plating respectively. the most common type of fractures was a1 which was observed in twenty five patients. initial :::::union::::: and non:::::union::::: occurred in sixty three and thirteen patients respectively. eight patients had non:::::union::::: in plating group and five of twenty seven patients in im nailing group. eleven of twenty seven patients in im nailing group suffered from mal:::::union::::: while only four patients in the other group had this complication. conclusion: the plating technique in comparison with im nailing has a satisfactory functional outcome. the technique has a lower incidence of mal:::::union::::: and non:::::union:::::, and it should be recommended as a good treatment option for the management of extra-articular closed fracture of distal tibia.
منابع مشابه
Assessment of the treatment outcome of closed extra-articular distal tibia fracture: IM nailing vs plating
Abstract Background: The tibial diaphyseal fractures are the most common type of long bone fractures encountered by most orthopedic surgeons. In accordance with descriptive indices of tibia fractures on the basis of their location in the bone, distal tibia fractures have the second incidence of all tibia fractures after the middle tibia fractures. The purpose of the study was to asses...
متن کاملDorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial.
INTRODUCTION Fractures of the distal radius are very common and mainly occur in the elderly. There has been an increasing use of locked volar plate fixations which report satisfactory results. However, some authors advocate the use of nail fixation. HYPOTHESIS The aim of this study is to compare dorsal nail plate versus locked volar plate fixation in the treatment of distal radius fractures w...
متن کاملRetrograde Nailing versus Locked Plating of Extra-Articular Distal Femoral Fractures: Comparison of 36 Cases
OBJECTIVE The purpose of this study was to retrospectively evaluate the use of locked plating (LP) and retrograde nailing (RN) for treating extra-articular distal femoral fractures. MATERIALS AND METHODS From January 2004 to March 2009, 36 patients with extra-articular distal femoral fractures were surgically treated at our Trauma Center. The patients were divided into two groups according to...
متن کاملIntramedullary nailing versus plating for distal tibia fractures without articular involvement: a meta-analysis
BACKGROUND The choice between intramedullary (IM) nailing or plating of distal tibia fractures without articular involvement remains controversial. A meta-analysis of randomized controlled trials (RCTs) and observational studies was performed to compare IM nailing with plating for distal tibia fractures without articular involvement and to determine the dominant strategy. MATERIALS AND METHOD...
متن کاملAnterolateral Versus Medial Plating of Distal Extra-articular Tibia Fractures: A Biomechanical Model.
Both medial and anterolateral plate applications have been described for the treatment of distal tibia fractures, each with distinct advantages and disadvantages. The objective of this study was to compare the biomechanical properties of medial and anterolateral plating constructs used to stabilize simulated varus and valgus fracture patterns of the distal tibia. In 16 synthetic tibia models, a...
متن کاملUnion Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures
Background: Distal tibia fractures are among the most common bony injuries, with a significant rate of nonunion anddelayed union. There are multiple methods for the management of distal tibia fractures. Among the plating methods,there are bridge plating and compression plating techniques. There is still a lack of evidence about whether one methodhas a higher rate of union than...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
medical journal of islamic republic of iranجلد ۲۳، شماره ۳، صفحات ۱۲۷-۱۳۱
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023