effect of drill bit angle on temperature rise during mandible drilling with finite element method

نویسندگان

علی پیرنیسیانی

نیما جمشیدی

محسن صراف بیدآبادی

نوید سلطانی

چکیده

introduction: excessive temperature rise during drilling of the mandible for dental implant placement might damage adjacent osseous tissues. various factors affect temperature rise, including the geometrical parameters of surgical drills, one of which is the drill bit head angle. the aim of this research was to determine suitable drill bit head angle to induce minimum temperature rise during mandible drilling operation for dental implant placement. materials and methods: in this research, the finite element analysis software deform-3d ver 6.1 was used for mandibular cortical bone drilling. to this end, three drill bits with different head angles of 70, 90 and 118 degrees were designed in this software. three-dimensional modeling of the mandible was performed using ct scan images and mimics 10.01 software. to place the drill bit on the mandibular model, catia v5r19 software was used to remove a tooth from the distal end of the mandibular model. finally, to perform the drilling operation, the model of the mandible was imported to deform-3d ver 6.1 software in stl format. results: at the end of these simulations, the diagrams of maximum heat generated in mandibular bone during drilling operation and mean temperatures were obtained. the results showed that the drill bit with 70° head angle resulted in the minimum mean temperature of 75.4ºc compared to 90 and 118 degrees with mean temperatures of 81.1°c and 93.4°c, respectively. conclusion: the results indicated that drill bit with 70° head angle is more appropriate for mandibular bone drilling operation than other larger bit angles.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی تحلیل حرارتی عددی سوراخکاری استخوان فک در جراحی مرتبط با کاشت ایمپلنت

Background and Aims: Optimization drilling parameters in order to temperature decrease during creation of hole in the bone is an interested issue. The aim of this study was to achieve optimum values of drilling parameters based on the creation of minimum temperature during jawbone drilling. Materials and Methods: In this study two models of mandible and maxilla was created and teeth 2, 5...

متن کامل

Temperature rise of alveolar bone during dental implant drilling using the finite element simulation

In this study, a three-dimensional elastic-plastic dynamic finite element model is used to simulate the alveolar bone temperature rise during dental implant drilling. An experimental setup was designed to verify the feasibility of the proposed dynamic finite element model. The peak bone temperature within the alveolar bone is investigated through both simulations and experiments. The results in...

متن کامل

FEM investigation of drilling conditions on heat generation during teeth implantation

Abstract The first step of implanting teeth is to drill a hole in the jaw bone. Excessive temperature produced during drilling is one of the destructive factors for bony tissue. If the temperature generation during surgical drilling exceeds the critical temperature, it could lead to osteonecrosis. This research intends to study drilling parameters such as drilling speed, feed rate, cooling con...

متن کامل

Drilling of bone: a robust automatic method for the detection of drill bit break-through.

The aim of this investigation is to devise a robust detection method for drill bit break-through when drilling into long bones using an automated drilling system that is associated with mechatronic assisted surgery. This investigation looks into the effects of system compliance and inherent drilling force fluctuation on the profiles of drilling force, drilling force, drilling between successive...

متن کامل

Study on Fe3O4 Magnetic Nanoparticles ‎Size Effect on Temperature Distribution ‎of Tumor in Hyperthermia: A Finite ‎Element Method ‎

   In recent years, Hyperthermia has been used as an emerging technique for cancer treatment, especially for localized tumors. One of the promising cancer treatment approaches is magnetic nanoparticle (MNPs) Hyperthermia. In this theoretical work, the temperature distribution of a common tumor over the different sizes of Fe3O4 magnetic nanoparticles, namely 25, 50, 100, and 200 nm, was stud...

متن کامل

the effect of e-64 on the developmental competence of sheep cocs during in vitro maturation

in the present study, the effect of e-64 at different concentrations (0.5, 1, 5 and 10 µm) added to (1) the ivm medium on oocyte nuclear maturation and developmental competence of ovine oocytes, and (2) to the ivc medium on embryonic development of ovine embryos were investigated.

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
مجله دانشکده دندانپزشکی اصفهان

جلد ۱۱، شماره ۴، صفحات ۲۸۴-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023