comparison of screw access channel obturation on the retention of implant-supported fixed restorations
نویسندگان
چکیده
introduction: a limited number of studies have evaluated factors influencing the retention of fixed prostheses cemented to implant abutments. the aim of this study was to compare the effect of varying degrees of screw access channel obturation on retention of implant-supported cast fixed restorations. materials & methods: in this experimental study, 40 implant abutments with a diameter of 4.5 mm were connected to implant analogues and mounted in acrylic resin blocks. the samples were divided into four groups randomly. in groups 1, 2 and 3, the access channels were obturated with a 1-mm, 2-mm and 3-mm free space and in group 4 the access channels were obturated completely with silicone material and the copings were cemented with a temporary bonding agent containing eugenol. after thermocycling, the retention of the samples was evaluated in a universal testing machine under 5000 n at a strain rate of 5 mm/min. data were analyzed with one-way anova and post hoc lsd test (α = 0.05). results: the mean retention for the group with abutment access channel completely obturated was less than that in others. one-way anova showed statistically significant differences between the groups (p value = 0.032). the difference between the group with completely obturated access channels and the other groups was significant (p value < 0.05); however, the differences between the groups obturated with 1- mm , 2-mm and 3-mm free spaces were not statistically significant (p value > 0.05). conclusion: the retention of castings cemented to implant abutments might be influenced by the obturation mode of screw access channel. complete obturation of access channel with poly vinyl siloxane results in a decrease in retention.
منابع مشابه
Effects of abutment and screw access channel modification on dislodgement of cement-retained implant-supported restorations.
This study investigated the influence of implant abutment and screw access channel modification on the retention of copings. Titanium abutment access openings were either left open or modified by placing two vent holes 3 mm from the occlusal edge and 180 degrees apart. Access openings sealed with a resin material were used as controls. Metal copings were cemented and subjected to tensile testin...
متن کاملInfluence of Sealing of the Screw Access Hole on the Fracture Resistance of Implant-Supported Restorations.
The purpose of this study was to assess the influence of sealing of the screw access hole (SAH) on the fracture resistance of metal-ceramic implant-supported restorations. UCLA abutments were used to make 30 implant-retained mandibular molar restorations and divide equally into three groups: Group SRS: screw-retained restorations with SAH sealed; Group SRNS: screw-retained restorations with SAH...
متن کاملthe effect of explicit teaching of metacognitive vocabulary learning strategies on recall and retention of idioms
چکیده ندارد.
15 صفحه اولthe washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests
در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است
15 صفحه اولA systematic review of screw- versus cement-retained implant-supported fixed restorations.
PURPOSE To systematically evaluate the survival and success of screw- versus cement-retained implant crowns. MATERIALS AND METHODS The authors performed an electronic search of nine databases using identical MeSH phrases. Systematic evaluation and data extraction of the articles from 1966 through 2007 were completed by three reviewers and two clinical academicians. The major outcome variable ...
متن کاملScrew Joint Stability in Conventional and Abutment-Free Implant-Supported Fixed Restorations.
PURPOSE Procera Implant Bridges (PIBs) do not engage supporting implant shoulders and are fixed using comparably long retention screws. The aim of this in vitro clinical study was to determine the detorque values in PIBs and conventionally fabricated fixed dental prostheses (FDPs). MATERIALS AND METHODS Two groups of screw-retained implant-supported three-unit FDPs (n=10) were fabricated by m...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
مجله دانشکده دندانپزشکی اصفهانجلد ۱۲، شماره ۱، صفحات ۸۱-۰
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023