matlab-based software for size-specific dose estimation (ssde) in computed tomography examinations
نویسندگان
چکیده
primary and widely in use computed tomography (ct) dose descriptor is a volumetric ct dose index (ctdiv) that is usually measured by a pencil ionization chamber with active length of 100mm and polymethyl methacrylate (pmma) phantom. ctdiv depends on scan parameters such as mas, kv, collimation, tube rotation time but is independent of patient’s size and shape. for the purpose of a good estimation of dose received by the patients, american association of physicists in medicine (aapm) published the conversion factors for both 16 and 32cm (head and body phantoms respectively); through this, users can extract conversion factors according to lateral (lat) and/or anterior-posterior (ap) sizes and calculate real ctdiv. since this procedure is time consuming, we designed matlab-based software to reduce such calculations. to design the software, gui toolbar of matlab software was used. to test the software, scan parameters of two patients for head and pelvis scan were read from pacs and lateral (lat) and anterior-posterior (ap) sizes were measured. finally, ssdes were calculated for two patients by the software. the software can be measured based on ap and/or lat measures and/or in special cases (under the age of 18) through patients' age.
منابع مشابه
Effect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations
Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...
متن کاملPatient effective dose estimation for routine computed tomography examinations in Iran
Background: The present study intended to determine and report patient effective dose on the basis of patients and exposure data. Materials and methods: A nationwide computed tomography (CT) survey was provided as a report of patient doses in 2015-2016. Scan details were collected for nearly 2,000 adults and children in four age groups subjected to CT examinations. From total 565 CT scanners in...
متن کاملPatient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria
Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT exa...
متن کاملDiagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria
Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملSize specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT
Objective(s): Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE...