matlab-based software for size-specific dose estimation (ssde) in computed tomography examinations

نویسندگان

daryoush khoramian department of medical physics, faculty of medicine, tarbiat modares university, tehran, iran.

soroush sistani department of medical physics, semnan university of medical sciences, semnan, iran.

چکیده

primary and widely in use computed tomography (ct) dose descriptor is a volumetric ct dose index (ctdiv) that is usually measured by a pencil ionization chamber with active length of 100mm and polymethyl methacrylate (pmma) phantom. ctdiv depends on scan parameters such as mas, kv, collimation, tube rotation time but is independent of patient’s size and shape. for the purpose of a good estimation of dose received by the patients, american association of physicists in medicine (aapm) published the conversion factors for both 16 and 32cm (head and body phantoms respectively); through this, users can extract conversion factors according to lateral (lat) and/or anterior-posterior (ap) sizes and calculate real ctdiv. since this procedure is time consuming, we designed matlab-based software to reduce such calculations. to design the software, gui toolbar of matlab software was used. to test the software, scan parameters of two patients for head and pelvis scan were read from pacs and lateral (lat) and anterior-posterior (ap) sizes were measured. finally, ssdes were calculated for two patients by the software. the software can be measured based on ap and/or lat measures and/or in special cases (under the age of 18) through patients' age.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations

Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...

متن کامل

Patient effective dose estimation for routine computed tomography examinations in Iran

Background: The present study intended to determine and report patient effective dose on the basis of patients and exposure data. Materials and methods: A nationwide computed tomography (CT) survey was provided as a report of patient doses in 2015-2016. Scan details were collected for nearly 2,000 adults and children in four age groups subjected to CT examinations. From total 565 CT scanners in...

متن کامل

Patient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria

Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT exa...

متن کامل

Diagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria

Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...

متن کامل

Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...

متن کامل

Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT

Objective(s): Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of paramedical sciences

جلد ۷، شماره ۲، صفحات ۳۵-۳۸

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023