hplc determination of acyclovir in human serum and its application in bioavailability studies

نویسندگان

j emami

n bazargan

a ajami

چکیده

a sensitive, accurate and rapid reverse phase hplc method was described to quantitate levels of acyclovir in human plasma. the drug, internal standard (metronidazole) and phosphate buffer (0.05 m) were added to serum samples and vortexed for 30 sec. a mixture of isopropyl alcohol:dichloromethane (60:40) was then added and vortexed for 3 min. samples were centrifuged and the supernatant layer was separated, evaporated to dryness under nitrogen gas stream, reconstituted in mobile phase and, an aliquot of 50 μl was analyzed on a μ -bondapack c 18 (250 × 3.9 mm) column, with 3% acetonitrile in deionised water and 0.5% orthophosphoric acid, (ph 2.5) at 254 nm. the standard curve covering 100-1500 ng/ml concentration range, was linear, relative errors were within 0.79 to 17.4% and the cv% ranged from 3.81 to 18.2. the limits of quantitation and detection of the method were 100 ng/ml and 25 ng/ml, respectively. the method was suitable for bioavailability and pharmacokinetic studies of acyclovir in humans and applied in a randomized, two-way cross over bioequivalence study of two different acyclovir preparations with twelve subjects and with a one-week washout period.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HPLC determination of acyclovir in human serum and its application in bioavailability studies

A sensitive, accurate and rapid reverse phase HPLC method was described to quantitate levels of acyclovir in human plasma. The drug, internal standard (metronidazole) and phosphate buffer (0.05 M) were added to serum samples and vortexed for 30 sec. A mixture of isopropyl alcohol:dichloromethane (60:40) was then added and vortexed for 3 min. Samples were centrifuged and the supernatant layer wa...

متن کامل

application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples

ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...

15 صفحه اول

extraction and characterization of allium irancum plant extract and its application in the green synthesis of silver nano particles and oxidation of thiocarbony1 compounds

سنتز سبز نانوذرات فلزی (nps) درسالهای اخیر توجه بسیارزیادی را به خود جلب کرده است. زیرا این پروتوکل کم هزینه وسازگار با محیط زیست از روش های استاندارد سنتز. در این پایان نامه ما گزارش میکنیم یک روش ساده و سازگار با محیط زیست برای سنتز نانوذرات نقره با استفاده از محلول آبی عصاره گیاه allium iranicum به عنوان یک عامل کاهش دهنده ی طبیعی. نانو ذرات نقره مشخص شد با استفاده از تکنیک های uv-visible، x...

HPLC determination of bezafibrate in human plasma and its application to pharmacokinetics studies.

An isocratic high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of bezafibrate in biological fluids. Bezafibrate was separated on a C(18) analytical column (150 x 4.6 mm i.d., 5 microm particle size) with 0.01 M phosphate buffer (pH 3.5)-acetonitrile-methanol (50:40:10) as mobile phase at a flow rate of 1.0 mL/min. The UV detector was set to ...

متن کامل

Determination of fenticonazole in human plasma by HPLC–MS/MS and its application to pharmacokinetic studies☆

Two simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) methods were developed and validated for the determination of fenticonazole in human plasma after percutaneous and intravaginal administration. Mifepristone was used as an internal standard (IS), and simple protein precipitation by acetonitrile containing 2% acetic acid was utilized for extract...

متن کامل

Validated HPLC method for determination of caffeine level in human plasma using synthetic plasma: application to bioavailability studies.

Several high-performance liquid chromatography (HPLC) methods have been described for the determination of caffeine in human plasma. However, none have been cross validated using synthetic plasma. The present study describes a simple and reliable HPLC method for the determination of the caffeine level in human plasma. Synthetic plasma was used to construct calibration curves and quality control...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
research in pharmaceutical sciences

جلد ۴، شماره ۱، صفحات ۴۷-۰