background community acquired pneumonia (cap) is a common health concern and the main mortality factor worldwide. nowadays, legionella pneumophila is one of the most common microorganisms responsible for cap. we designed this study to investigate the antigen test as a useful, simple and rapid test for early diagnosis of legionella pneumophila. materials and methods we enrolled 118 patients (32 females and 86 males) with cap, copd and asthma in masih daneshvari medical center during 2004 –5. clinical and microbiological evaluations were performed. sputum culture and legionella urinary antigen tests were carried out. results different types of bacteria were isolated from 118 patients. the most frequently isolated respiratory microorganisms were: streptococcus pneumonia (88%), candida spp. (76.2%), beta-hemolytic streptococcus (61.8%), neiseria spp (44.4%), staphylococcus (40.6%), klebsiella spp (27.1%), fungi (16.1%), e.coli (8.4%), and pseudomonas spp (5.1%). no legionella was detected from sputum specimens. legionella urinary antigen testing was revealed to be positive in 3 males. conclusion urinary antigen test is a particularly useful, simple and rapid test since it is often easier to obtain urine in ill patients. the results can be available within hours and it is also reliable enough to commence treatment.
منابع مشابه
Laboratory Diagnosis of Pneumonia by Detection of Urinary Antigen Test of Legionella Pnuemophilia
Background and Aims: Legionnaires’ disease is seen in sporadic and epidemic form. The most prevalent cause is Legionella pnuemophilia (L.pneumophila), which produces a severe disease in vulnerable individuals with a high fatality rate. This study was conducted due to the wide and universal distribution of the Legionnaires’ disease, lack of conventional and accessible diagnostic meth...
متن کاملCentrifugal ultrafiltration method for rapid concentration of Legionella pneumophila urinary antigen.
Detection of Legionella pneumophila antigen in urine by enzyme immunoassay (EIA) or by immunochromatographic testing (ICT) has proven rapid, sensitive, and specific for diagnosing legionellosis (2, 3, 5, 6). Although it requires added processing time, the use of concentrated urine (CU) obtained by selective ultrafiltration significantly improves the sensitivity (1) of antigen detection. We asse...
متن کاملCan we truly rely on the urinary antigen test for the diagnosis? Legionella case report
It is critical to diagnose and treat Legionella pneumonia (LP) immediately after infection because of the associated high mortality. The urine antigen test (UAT) is often used for the diagnosis of LP; however, it cannot detect the serogroups of all Legionella species. A detained medical history and several clinical findings such as liver enzyme elevation and hyponatremia are useful in diagnosis...
متن کاملComparison of diagnostic sensitivities of three assays (Bartels enzyme immunoassay [EIA], Biotest EIA, and Binax NOW immunochromatographic test) for detection of Legionella pneumophila serogroup 1 antigen in urine.
The Bartels enzyme immunoassay (EIA), Biotest EIA, and Binax NOW immunochromatographic test (ICT) urinary antigen kits for the detection of Legionella pneumophila serogroup 1 were compared using 178 frozen urine samples. When nonconcentrated urine samples were used, the sensitivity levels of both enzyme EIAs were significantly higher than the sensitivity level of the ICT (Bartels EIA, 71.3%; Bi...
متن کاملthe test for adverse selection in life insurance market: the case of mellat insurance company
انتخاب نامساعد یکی از مشکلات اساسی در صنعت بیمه است. که ابتدا در سال 1960، توسط روتشیلد واستیگلیتز مورد بحث ومطالعه قرار گرفت ازآن موقع تاکنون بسیاری از پژوهشگران مدل های مختلفی را برای تجزیه و تحلیل تقاضا برای صنعت بیمه عمر که تماما ناشی از عدم قطعیت در این صنعت میباشد انجام داده اند .وهدف از آن پیدا کردن شرایطی است که تحت آن شرایط انتخاب یا کنار گذاشتن یک بیمه گزار به نفع و یا زیان شرکت بیمه ...
15 صفحه اولBinax and biotest Legionella urinary antigen kits.
The article of Robert F. Benson et al. entitled “Evaluation of the Binax and Biotest urinary antigen kits for detection of Legionnaires’ disease due to multiple serogroups and species of Legionella” (1) states the following in the abstract: “Eighteen were positive with the Binax kit, and 13 were positive with the Biotest.” This statement is misleading since data in both the article and Table 1 ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
archives of clinical infectious diseasesجلد ۲، شماره ۱، صفحات ۵-۸
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023