impact of stepwise sodium and ultra filtration profiles and dialysis solution flow rate profile on dialysis adequacy

نویسندگان

nahid shahgholian

azam salehi

mojgan mortazavi

چکیده

abstract background: inadequate dialysis is one of the main causes of mortality of the patients undergoing hemodialysis. the methods that lead to improvement of dialysis adequacy in these patients are of great importance due to them causing an improvement of quality of life. as numerous factors can play a role in improvement of dialysis adequacy, the present study aimed to investigate the level of impact of stepwise sodium and ultra filtration profiles and dialysis solution flow rate profile on dialysis adequacy. materials and methods: this is a cross-over clinical trial conducted on 32 patients selected from two hemodialysis centers in isfahan in 2013. the patients were assigned to two identical groups through random allocation, and each patient in group 1 underwent hemodialysis for four routine dialysis sessions, four stepwise sodium and ultra filtration profile sessions, and four sessions by stepwise dialysis solution flow rate profile. the patients in group 2 underwent hemodialysis for four sessions of stepwise dialysate flow rate profile, four sessions of stepwise sodium and ultra filtration profiles, and four sessions of routine dialysis method. dialysis adequacy was on line calculated by kt/v ratio in each session, and was analyzed by repeated measure analysis of variance (anova), least significant difference (lsd) post-hoc test, and independent t-test. results: means of dialysis adequacies were 1.239 (0.25) in the routine method, 1.407 (0.26) in stepwise sodium and ultra filtration profiles, and 1.414 (0.26) in dialysis solution flow rate profile. there was a significant difference between the routine method and the other two profiles (p < 0.05), but the difference in dialysis adequacy means in the two profi le methods was not significant (p > 0.05). mean scores of dialysis adequacy in the three treatment methods in the two groups showed that the sequence of methods had no effect on treatment outcome (p > 0.05). conclusions: stepwise sodium and ultra filtration profiles and stepwise dialysis solution flow rate profile are suggested as they can increase dialysis adequacy compared to the routine method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the Effects of Stepwise Sodium and Ultrafiltration Profile on Dialysis Adequacy

Background: One of the leading causes of disability and mortality among patients receiving hemodialysis (HD) is HD inadequacy. Enhancing HD adequacy can improve the prognosis for these patients. Objectives: This study sought to investigate the effects of stepwise sodium and ultrafiltration profile on HD adequacy. Patients and Methods: This crossover clinical trial was conducted on 30 patients, ...

متن کامل

Impact of Jacobson Relaxation on Dialysis Adequacy in ElderlyHemodialysis Patients

Background: Dialysis adequacy is one of the determining factors for survival in elderly patients. Improving the dialysis adequacy highly affects the remission and prognosis of old dialysis patients. Current study was conducted to evaluate the effects of Jacobson relaxation technique on dialysis adequacy in elderly people, who are under dialysis treatment. Methods: ods: This is a clinical trial...

متن کامل

بررسی تاثیر تغییر غلظت سدیم محلول دیالیز همراه با تغییر سرعت اولترافیلتراسیون بر افت فشارخون حین دیالیز و وزن بین جلسات دیالیز

Background and purpose:Intradialytic hypotension (IDH) is the most frequent complicationin patients receiving haemodialysis (HD) that poses most problems for patient and treatment team. The use of sodiumprofile and ultra filtration (UF) profile is one of the preventive methods that have been recently introduced. However, increased intradialytic weight gain (IDWG) has been described as the sid...

متن کامل

تأثیر ترکیب دو نوع پروفایل سدیم و اولترافیلتراسیون بر فشارخون سیستولی و دیاستولی در طول فرآیند دیالیز در بیماران تحت درمان با همودیالیز

Background & Aim: Intradialytic hypotension is the most frequent complication in patients receiving haemodialysis (HD). This complication not only contributes to the illness of the patients, but also decreases the efficacy of the HD. So, hypotension prevention is a major challenge for medical team, especially for nurses. One of the preventive methods that have recently been presented is the use...

متن کامل

Prolactin and adequacy of dialysis

Hyperprolactinemia is a common endocrinal alteration in chronic renal failure, Several investigators examined the serum concentration of prolactin in patients with chronic renal failure and found it to be elevated. The aim of the study: is to evaluate the relation between adequacy of dialysis and levels of serum Prolactin in long term hemodialysis patients, in order to clarify if adequate dialy...

متن کامل

Measured Glomerular Filtration Rate at Dialysis Initiation and Clinical Outcomes of Indian Peritoneal Dialysis Patients

The optimal time for dialysis initiation remains controversial. Studies have failed to show better outcomes with early initiation of hemodialysis; even a few had shown increased adverse outcomes including poorer survival. Few studies have examined the same in patients on peritoneal dialysis (PD). Measured glomerular filtration rate (mGFR) not creatinine-based estimated GFR is recommended as the...

متن کامل