reproducible x-ray projection geometry in endodontic practice
نویسندگان
چکیده
introduction: clinical application of radiography in endodontic practice is affected by reproducibility in the orientation of the x-ray source, image receptor and object. the inability of dentists to locate intra oral films or sensors in appropriate positions in different cases can cause complications in the performance of endodontic therapy. commercially available film holder (endoray) and conventional imaging methods seem to be insufficient and difficult to perform. the purpose of this investigation was to develop a novel and easily performed device for endodontic radiography and to asses its reproducibility and accuracy in vitro. materials and methods: the present work surveys and evaluates the design steps of a newly constructed film holder with modified bite block and a beam guiding device, in an attempt to perform a diagnostic study. references wires and balls were attached on the film holder and to the alveolar crest of maxillary molar region inserted in the conventional phantom for measuring the projection errors relative to the film holder and repositioning .one hundred and twenty radiographs of a conventional phantom were taken by one of the authors and by two dental students using the novel device and endoray. results: the %95 ci for precision of radiologist and one of the students was less than 8 (7.313 ± 0.1989) .the %95 ci for precision of the other student was less than 12 (10.941 ± 0.4217). there was no significant difference (p= 0.679), regarding the interoperator precision, between radiologist and first student. there was significant difference between second student and the others (p<0.05). no significant difference was noted between the radiographs achieved by the endoray and new device. conclusion: the novel device appears to be a potential means of obtaining reproducible radiographs in endodontic practice. further research is needed however, to study in vivo aspects, reproducibility and accuracy.
منابع مشابه
Soft-x-ray projection lithography
Soft-x-ray projection imaging is demonstrated by the use of 14-nm radiation from a laser plasma source and a single-surface multilayer-coated ellipsoidal condenser. Aberrations in the condenser and the Schwarzschild imaging objective are characterized and correlated with imaging performance. A new Schwarzschild housing, designed for improved alignment stability, is described.
متن کاملRay-tracing and Interferometry in Schwarzschild Geometry
Here, we investigate the possible optical anisotropy of vacuum due to gravitational field. In doing this, we provide sufficient evidence from direct coordinate integration of the null-geodesic equations obtained from the Lagrangian method, as well as ray-tracing equations obtained from the Plebanski’s equivalent medium theory. All calculations are done for the Schwarzschild geometry, which resu...
متن کاملMR to X-Ray Projection Image Synthesis
Hybrid imaging promises large potential in medical imaging applications. To fully utilize the possibilities of corresponding information from different modalities, the information must be transferable between the domains. In radiation therapy planning, existing methods make use of reconstructed 3D magnetic resonance imaging data to synthesize corresponding Xray attenuation maps. In contrast, fo...
متن کاملRecent developments in X-ray projection microscopy and X-ray microtomography applied to materials science
After a long period of sleeping, there is recently a spectacular revival of X-ray microscopy due to the progress in X-ray sources (synchrotron radiation), X-ray optics, and X-ray detectors. However most of the attempts in this field concern the use of soft X-rays to observe, with an improved resolution, biological specimens in their wet environment. In opposition to these trends, we try to demo...
متن کاملThe effect of nurses' virtual learning on knowledge and practice of observing X-Ray protection principles
Background: Upgrading the level of staffs knowledge in this regard can play an important role in reducing the complications of radiation in the community. Materials and Methods: This randomized clinical trial was coducted on 90 nurses. To collect data, a demographic information form and a radiation protection and X-ray protective questionnaire and a performance checklist were used. Education...
متن کاملCygnus X-1: X-ray Emission Mechanism and Geometry
On 1996 May 10, the All-Sky Monitor aboard RXTE revealed that Cyg X–1 started a transition from its hard state to soft state (Cui 1996). Throughout this interesting episode, snapshots were taken with more sensitive detectors on ASCA, RXTE, and CGRO to monitor the temporal and spectral variability of the source over a broad energy range. The results (both spectral and temporal) from these observ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian endodontic journalجلد ۱، شماره ۲، صفحات ۵۳-۵۶
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023