root canal cleaning efficacy of rotary and hand files instrumentation in primary molars

نویسندگان

kiumars nazari moghaddam department of endodontics, dental school, shahed university of medical sciences, tehran, iran

majid mehran department of pediatrics, dental school, shahed university of medical sciences, tehran, iran

hamideh farajian zadeh dentist, private practice, tehran, iran

چکیده

introduction: pulpectomy of primary teeth is commonly carried out with hand files and broaches; a tricky and time consuming procedure. the purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous molars using hand k-files and flex master rotary system. materials and methods: in this study, 68 canals of 23 extracted primary molars with at least two third intact roots and 7-12 mm length were selected. after preparing an access cavity, k-file size #15 was introduced into the root canal and india ink was injected with an insulin syringe. sixty samples were randomly divided in to experimental groups in group i (n=30), root canals were prepared with hand k-files; in group ii (n=30), rotary flex master files were used for instrumentation, and in group iii 8 remained samples were considered as negative controls. after clearing and root sectioning, the removal of india ink from cervical, middle, and apical thirds was scored. data was analyzed using student's t-test and mann-whitney u test. results: there was no significant difference between experimental groups cleaning efficacy at the cervical, middle and apical root canal thirds. only the coronal third scored higher in the hand instrumented group (p<0.001). instrumentation with flex master rotary files was significantly less time consuming (p<0.001). conclusion: although there was no difference in cleanliness efficacy at the apical and middle thirds, the coronal third was more effectively cleaned with hand files. predictably, time efficiency was a significant advantage with rotary technique.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Root Canal Cleaning Efficacy of Rotary and Hand Files Instrumentation in Primary Molars

INTRODUCTION Pulpectomy of primary teeth is commonly carried out with hand files and broaches; a tricky and time consuming procedure. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous molars using hand K-files and Flex Master rotary system. MATERIALS AND METHODS In this study, 68 canals of 23 extracted primary molars with a...

متن کامل

Comparison of Cleaning Efficacy and Instrumentation Time of Reciproc and Mtwo Rotary Systems in Primary Molars

Background and Aim: Pulpectomy of primary teeth is commonly performed with hand files and instruments. However, it is a time consuming procedure. Compared to hand files, rotary instrumentation has more advantages. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous mo-lars using Reciproc and Mtwo rotary systems. Materials an...

متن کامل

comparison of cleaning efficacy and instrumentation time in primary molars: mtwo rotary instruments vs. hand k-files

introduction: pulpectomy is the preferred treatment for restorable primary teeth with symptomatic irreversible pulpitis or periradicular lesion. considering the rather new application of rotary files for pulpectomy of primary teeth, the aim of this study was to compare the cleaning efficacy and instrumentation time of hand k-files and mtwo rotary system for preparation of human primary molars. ...

متن کامل

Comparison of Cleaning Efficacy and Instrumentation Time in Primary Molars: Mtwo Rotary Instruments vs. Hand K-Files

INTRODUCTION Pulpectomy is the preferred treatment for restorable primary teeth with symptomatic irreversible pulpitis or periradicular lesion. Considering the rather new application of rotary files for pulpectomy of primary teeth, the aim of this study was to compare the cleaning efficacy and instrumentation time of hand K-files and Mtwo rotary system for preparation of human primary molars. ...

متن کامل

A COMPARISON OF Ni-Ti ROTARY AND HAND FILES INSTRUMENTATION IN PRIMARY MOLARS

The aim of the study was to compare the manual and rotary endodontic instruments focusing on risk of perforation when the whole root canal length is instrumented as well as the time required for preparation in primary teeth Fifty four teeth were divided randomly into three groups.Group I: The root canals were prepared manually with K-files. Group II : ProTaper instruments were used in a crown-d...

متن کامل

Manual and rotary instrumentation techniques for root canal prepa- ration in primary molars

Introduction: Although rotary instrumentation has been widely studied in permanent dentition, it is a rather new field of study concerning primary teeth. Purpose: We aimed to evaluate apical displacement and time needed for instrumentation of root canals of primary molars by manual and rotary techniques. Materials and Methods: Root canals of 144 extracted first and second primary maxillary mola...