an in vitro comparison of root canal system prepared with either hand or rotary instruments

نویسندگان

azza a dafalla lecturer of conservative dentistry, school of dentistry, africa university of medical science, khartoum, sudan

neamat hassan abu-bakr department of conservative dentistry, faculty of dentistry, university of khartoum, khartoum, sudan

yahia e ibrahim department of conservative dentistry, faculty of dentistry, university of khartoum, khartoum, sudan

چکیده

introduction: the aim of the present study was to compare hand stainless steel k-files and nickel-titanium profile 0.04 taper 29 series rotary instruments for their efficiency, procedural errors and time consumed in preparation of root canal system. materials and methods: a total of 46 maxillary and mandibular first premolars extracted for orthodontic purposes were collected (two contralateral teeth from each individual). the samples were divided into two groups of 34 canals each. teeth in the first group were prepared with stainless steel hand k-files while the second groups were prepared with profile 0.04 taper series 29 rotary files. preparation period was recorded for both groups. impression material was introduced into the prepared canals so that the replica of prepared canals was achieved. these were assessed under stereomicroscope to assess the efficiency in preparing canals in respect to canal smoothness, ability of impression material to flow and quality of taper. statistical analyses were performed using t-test, chi-square and fishers exact tests. results: results showed significantly shorter preparation time for profile than k-file. 8.8% of the canals prepared with k-files showed canal blockage, while all canals prepared with profile remained patent. alterations in working length working distance appeared in 23.5% of canals prepared with k-file and 11.7% in canals prepared with profile. failed instruments in k-files were significantly higher, mostly deformation (p<0.001). profiles failed instruments were in the form of fracture and no deformation was detected. both systems showed unsatisfactory walls smoothness and flow. conclusion: within the limitation of this study it was concluded that profile 0.04 taper series 29 rotary systems prepare canals more rapidly, and have lower incidences of fracture and blockages, and only limited loss of working length. canal preparation with k-file was time consuming and showed higher incidence of deformed instruments; overall, rotary instruments seem to offer greater advantages.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in vitro comparison of root canal system prepared with either hand or rotary instruments

INTRODUCTION The aim of the present study was to compare hand stainless steel K-files and Nickel-Titanium Profile 0.04 taper 29 series rotary instruments for their efficiency, procedural errors and time consumed in preparation of root canal system. MATERIALS AND METHODS A total of 46 maxillary and mandibular first premolars extracted for orthodontic purposes were collected (two contralateral ...

متن کامل

An in vitro comparison of hand and rotary instruments in preparing root canal system

Introduction: The aim of the present study was to compare hand stainless steel K-files and Nickel-titanium Profile 0.04 taper 29 series rotary instruments for their efficiency, procedural errors and time consumed in preparation of root canal system. Materials and Methods: A total of 46 maxillary and mandibular first premolars extracted for orthodontic purposes were collected (two contralateral ...

متن کامل

Evaluation of Root Canal Preparation Using Rotary System and Hand Instruments Assessed by Micro-Computed Tomography

BACKGROUND Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. MATERIAL AND METHODS Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth eac...

متن کامل

A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro)

A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro) Dr. MR. Sharifian* - Dr. MH. Nekoofar* - Dr. P. Motahari** - Dr. A. Tavakoli*** *-Assistant Professor of Endodontics Dept. – Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Oral and Maxillofacial Pathology Dept. – Facul...

متن کامل

CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study

BACKGROUND Controlled, uniformly tapered radicular preparation is a great challenge in endodontics. Improper preparation can lead to procedural errors like transportation of foramen, uneven dentine thickness, stripping of root canal, formation of ledge, zip, and elbow in curved canals. These procedural errors and their sequel can adversely affect the prognosis of treatment. AIM/OBJECTIVES The...

متن کامل

in vitro comparison of apically extruded debris during root canal preparation of mandibular premolars with manual and rotary instruments

background and aims. during root canal preparation, debris extruded beyond the apical foramen may result in periapical inflammation and postoperative pain. to date no root canal preparation method has been developed that extrudes no periapical debris. the purpose of this study was to identify a system leading to minimal extrusion of debris from the apical foramen. the study was conducted to com...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian endodontic journal

جلد ۵، شماره ۴، صفحات ۱۶۷-۱۷۳

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023