digital radiography with computerized conventional monitors compared to medical monitors in vertical root fracture diagnosis

نویسندگان

maryam tofangchiha assistant professor ,shahid beheshti university of medical sciences,dental faculty,oral medicine department

mamak adel

mahin bakhshi

mahsa esfehani

چکیده

introduction: vertical root fracture (vrf) is a complication which is chiefly diagnosed radiographically. recently, film-based radiography has been substituted with digital radiography. at the moment, there is a wide range of monitors available in the market for viewing digital images. the present study aims to compare the diagnostic accuracy, sensitivity and specificity of medical and conventional monitors in detection of vertical root fractures. material and methods: in this in vitro study 228 extracted single-rooted human teeth were endodontically treated. vertical root fractures were induced in 114 samples. the teeth were imaged by a digital charge-coupled device radiography using parallel technique. the images were evaluated by a radiologist and an endodontist on two medical and conventional liquid-crystal display (lcd) monitors twice. z-test was used to analyze the sensitivity, accuracy and specificity of each monitor. significance level was set at 0.05. inter and intra observer agreements were calculated by cohen’s kappa. results: accuracy, specificity and sensitivity for conventional monitor were calculated as 67.5%, 72%, 62.5% respectively; and data for medical grade monitor were 67.5%, 66.5% and 68% respectively. statistical analysis showed no significant differences in detecting vrf between the two techniques. inter-observer agreement for conventional and medical monitor was 0.47 and 0.55 respectively (moderate). intra-observer agreement was 0.78 for medical monitor and 0.87 for conventional one (substantial). conclusion the type of monitor does not influence diagnosis of vertical root fractures.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digital Radiography with Computerized Conventional Monitors Compared to Medical Monitors in Vertical Root Fracture Diagnosis

INTRODUCTION Vertical root fracture (VRF) is a complication which is chiefly diagnosed radiographically. Recently, film-based radiography has been substituted with digital radiography. At the moment, there is a wide range of monitors available in the market for viewing digital images. The present study aims to compare the diagnostic accuracy, sensitivity and specificity of medical and conventio...

متن کامل

Are Standard Pc Monitors Useful for the Diagnosis of Oral Lesions in Digital Radiography?

Cite this article: Araki K (2013) Are Standard Pc Monitors Useful for the Diagnosis of Oral Lesions in Digital Radiography? J Radiol Radiat Ther 2(2): 1028. Corresponding author Kazuyuki Araki, Department of Oral Diagnostic Sciences, Division of Radiology, Showa University School of Dentistry, Kitasenzoku 2-1-1, Ohta-ku, Tokyo, 145-8515, Japan, Tel: +81-3-3787-1151; Fax: +81-3-5702-5633; Email:...

متن کامل

Evaluation of Ultrasonography in Diagnosis of Nasal Fracture and Compared it with Plain Radiography in Dogs

Objective- One of the important causes of nasal fracture is a trauma that can be diagnosed in clinical examinations and diagnostic imaging but it should be noted that radiography may show false fractures in the nose. This study evaluates the value of ultrasonography in the diagnosis of nasal fractures and compared it with plain radiography. Design- Retrospective study. Animals- 12 d...

متن کامل

Comparison of Conventional Radiography and Digital Computerized Radiography in Patients Presenting to Emergency Department

OBJECTIVES To compare the differences between conventional radiography and digital computerized radiography (CR) in patients presenting to the emergency department. METHODS The study enrolled consecutive patients presenting to the emergency department who needed chest radiography. Quality score of the radiogram was assessed with visual analogue score (VAS-100 mm), measured in terms of millime...

متن کامل

diagnostic accuracy of conventional, digital and cone beam ct in vertical root fracture detection

introduction: vertical root fracture (vrf) is a common failure in endodontically treated teeth. due to vrf’s poor prognosis, a reliable and valid detection method is critical for treatment planning. conventional and digital radiographs are limited in vrf detection. recently, cone beam ct (cbct) system has been introduced. this study aimed to compare the diagnostic accuracy of these three imagin...

متن کامل

Digital Radiography Versus Conventional Radiography in Dentistry

Belma Muhamedagic, Lejla Muhamedagic Faculty of Medicine, University of Sarajevo, Bosnia and Herzegovina ography-RVG, Trophy Radiologie, Croissy Beaubourg, France [now Trophy, A Kodak Company, Rochester, N.Y.]). RVG is modern diagnostic method based on use of digital roentgen. Principle is use of so called CCD chip in RVG sensor (Figure 1) that put in patient’s mouth (3). The first dental digit...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian endodontic journal

جلد ۸، شماره ۱، صفحات ۱۴-۱۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023