accuracy of conventional and digital radiography in detecting external root resorption
نویسندگان
چکیده
introduction: external root resorption (err) is associated with physiological and pathological dissolution of mineralized tissues by clastic cells and radiography is one of the most important methods in its diagnosis. the aim of this experimental study was to evaluate the accuracy of conventional intraoral radiography (cr) in comparison with digital radiographic techniques, i.e. charge-coupled device (ccd) and photo-stimulable phosphor (psp) sensors, in detection of err. methods and materials: this study was performed on 80 extracted human mandibular premolars. after taking separate initial periapical radiographs with cr technique, ccd and psp sensors, the artificial defects resembling err with variable sizes were created in apical half of the mesial, distal and buccal surfaces of the teeth. ten teeth were used as control samples without any resorption. the radiographs were then repeated with 2 different exposure times and the images were observed by 3 observers. data were analyzed using spss version 17 and chi-squared and cohen’s kappa tests with 95% confidence interval (ci=95%). result: the ccd had the highest percentage of correct assessment compared to the cr and psp sensors, although the difference was not significant ( p =0.39). it was shown that the higher dosage of radiation increases the accuracy of diagnosis; however, it was only significant for ccd sensor ( p =0.02). also, the accuracy of diagnosis increased with the increase in the size of lesion ( p =0.001). conclusion: statistically significant difference was not observed for accurate detection of err by conventional and digital radiographic techniques.
منابع مشابه
Accuracy of Conventional and Digital Radiography in Detecting External Root Resorption
INTRODUCTION External root resorption (ERR) is associated with physiological and pathological dissolution of mineralized tissues by clastic cells and radiography is one of the most important methods in its diagnosis. The aim of this experimental study was to evaluate the accuracy of conventional intraoral radiography (CR) in comparison with digital radiographic techniques, i.e. charge-coupled d...
متن کاملComparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography
Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...
متن کاملAccuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption
PURPOSE The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. MATERIALS AND METHODS Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital ...
متن کاملDiagnostic accuracy of conventional radiography and digital radiography in detecting of root fractures (invitro study)
Purpose: Root fracture is a clinical problem which often is difficult to detect and diagnose. As the root fracture detection is based on demonstration of a fracture line or lines, radiographic examination is important. The aim of this study was to compare diagnostic efficacy of direct digital radiography with conventional radiography for detecting experimental root fractures. Materials & Method...
متن کاملComparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption
Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...
متن کاملcomparison of accuracy and observer agreement in the detection of simulated external root resorption using conventional digital radiography and digitally filtered radiography
introduction: external root resorption is a clinical problem that often cannot be detected clinically. thus, radiography plays a crucial role in its diagnosis. however, optimal radiographic quality with minimal radiation exposure {2.1 [en] verify english word/phrase choice} is an important factor in selecting the appropriate radiographic technique. the aim of this study was the comparison of ac...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian endodontic journalجلد ۹، شماره ۴، صفحات ۲۴۱-۲۴۵
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023