effect of metal artifacts on detection of vertical root fractures using two cone beam computed tomography systems
نویسندگان
چکیده
introduction: vertical root fracture (vrf) is common in endodontically treated teeth. conventional and digital radiographies have limitations for detection of vrfs. cone-beam computed tomography (cbct) offers greater detection accuracy of vrfs in comparison with conventional radiography. this study compared the effects of metal artifacts on detection of vrfs by using two cbct systems. methods and materials: eighty extracted premolars were selected and sectioned at the level of the cemento-enamel junction (cej). after preparation, root canals were filled with gutta-percha. subsequently, two thirds of the root fillings were removed for post space preparation and a custom-made post was cemented into each canal. the teeth were randomly divided into two groups ( n =40). in the test group, root fracture was created with instron universal testing machine. the control teeth remained intact. cbct scans of all teeth were obtained with either new tom vgi or soredex scanora 3d. three observers analyzed the images for detection of vrf. the sensitivity, specificity, positive predictive value (ppv) and negative predictive value (npv) for vrf detection and percentage of probable cases were calculated for each imaging system and compared using non-parametric tests considering the non-normal distribution of data. the inter-observer reproducibility was calculated using the weighted kappa coefficient. results: there were no statistically significant differences in sensitivity, specificity, ppv and npv between the two cbct systems. conclusion: the effect of metal artifacts on vrf detection was not significantly different between the two cbct systems. keywords: cast post; cbct; cone-beam computed tomography; vertical root fracture
منابع مشابه
Effect of Metal Artifacts on Detection of Vertical Root Fractures Using Two Cone Beam Computed Tomography Systems
INTRODUCTION Vertical root fracture (VRF) is common in endodontically treated teeth. Conventional and digital radiographies have limitations for detection of VRFs. Cone-beam computed tomography (CBCT) offers greater detection accuracy of VRFs in comparison with conventional radiography. This study compared the effects of metal artifacts on detection of VRFs by using two CBCT systems. METHODS ...
متن کاملComparison of five cone beam computed tomography systems for the detection of vertical root fractures.
INTRODUCTION This study compared the accuracy of cone beam computed tomography (CBCT) scans made by five different systems in detecting vertical root fractures (VRFs). It also assessed the influence of the presence of root canal filling (RCF), CBCT slice orientation selection, and the type of tooth (premolar/molar) on detection accuracy. METHODS Eighty endodontically prepared teeth were divid...
متن کاملThe Effect of Intra-Canal Posts on Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography in Detection of Vertical Root Fractures
Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics. Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) and greatly aids the diagnosis of VRFs but, metal artifacts has remained as a problem in VRF detection. This study evaluated the effect of intra canal posts on the diagnostic accuracy of CBCT and D...
متن کاملDetection of vertical root fractures by using cone-beam computed tomography: a clinical study.
INTRODUCTION Vertical root fractures of teeth (VRFs) often pose a diagnostic dilemma because of the difficulty in detection of these in intraoral radiographs except in certain cases with very distinct clinical findings. This often leads to unwarranted extraction of the tooth. Cone-beam computed tomography (CBCT) produces three-dimensional images and allows precise visualization and evaluation o...
متن کاملAssessment of vertical root fracture using cone-beam computed tomography
PURPOSE The aim of this study was to investigate the accuracy of cone-beam computed tomography (CBCT) in the diagnosis of vertical root fractures in a tooth with gutta-percha and prefabricated posts. MATERIALS AND METHODS This study selected 96 extracted molar and premolar teeth of the mandible. These teeth were divided into six groups as follows: Groups A, B, and C consisted of teeth with ve...
متن کاملThe effect of metal artifacts on the identification of vertical root fractures using different fields of view in cone-beam computed tomography
PURPOSE The aim of this study was to investigate the effects of metal artifacts on the accurate diagnosis of root fractures using cone-beam computed tomography (CBCT) images with large and small/limited fields of view (FOVs). MATERIALS AND METHODS Forty extracted molar and premolar teeth were collected. Access canals were made in all teeth using a rotary system. In half of the teeth, fracture...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian endodontic journalجلد ۱۰، شماره ۳، صفحات ۱۹۳-۱۹۸
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023