color stability of two bulk-fill composite resins

نویسندگان

f. ameri dept. of color physics, institute for color science and technology, tehran, iran.

m. abdo tabrizi dept. of restorative dentistry, school of dentistry, shahid beheshti university of medical sciences, tehran, iran.

a. ghassemi dept. of restorative dentistry, dental research center, school of dentistry, shahid beheshti university of medical sciences, tehran, iran.

a. najafi dept. of restorative dentistry, school of dentistry, shahid beheshti university of medical sciences, tehran, iran.

چکیده

objective: bulk-fill composites are a group of composite resins designed for easy and fast filling of large cavities. this study aimed to assess the color stability of bulk-fill composites subjected to xenon radiation and evaluate their color change (&deltae;) following polymerization. methods: in this in vitro experimental study, 30 specimens (4mm in height and 8mm in diameter) were fabricated of x-trafil and tetric n-ceram universal color bulk-fill composites and a2 shade of grandio composite (as control). bulk-fill composites were placed in the mold in 4mm thickness according to the manufacturers’ instructions. in the control group, composite was applied to the mold in two layers each with 2mm thickness. tetric and grandio composites were cured for 20 seconds and x-trafil was cured for 10 seconds with a led light-curing unit. a total of 15 specimens (five of each composite) were used for each test. for assessment of color change due to polymerization, l*, a* and b* color parameters were measured before and immediately after polymerization and also 30 days after immersion in distilled water in an incubator at 37°c and 70% humidity using a spectroradiometer. for xenon test, the specimens were subjected to color analysis after 48 hours of storage in distilled water. next, they were subjected to xenon lamp radiation in xenon environment chamber for 122 hours at 22°c and 25% humidity and then the color parameters were measured again. the mean and standard deviation (sd) of all values were calculated. one-way and repeated measures anova were used to compare &deltae; and &deltal; among the groups. tukey’s hsd test was used for pairwise comparisons. results: the value of &deltae; immediately after polymerization was the lowest for grandio (4.91) and the highest for tetric (9.44). thirty days after the polymerization, &deltae; was the lowest in grandio (3.07) and the highest in tetric (9.27) &deltae; showed a decreasing trend over time in all specimens. under xenon light radiation, grandio showed the lowest (1.50) and tetric showed the highest &deltae; (11.15). conclusion: following polymerization and under xenon lamp radiation, &deltae; of conventional composite was less than that of bulk-fill composites.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Color Stability of Two Bulk-Fill Composite Resins

Objective: Bulk-fill composites are a group of composite resins designed for easy and fast filling of large cavities. This study aimed to assess the color stability of bulk-fill composites subjected to xenon radiation and evaluate their color change (&DeltaE) following polymerization. Methods: In this in vitro experimental study, 30 specimens (4mm in height and 8mm in diameter) were fabricat...

متن کامل

Color Stability of the Bulk-Fill Composite Resins with Different Thickness in Response to Coffee/Water Immersion

We aimed to evaluate the color stability of bulk-fill and conventional composite resin with respect to thickness and storage media. Twenty specimens of a conventional composite resin (6 mm diameter and 2 mm thick) and 40 specimens of the bulk-fill Tetric EvoCeram composite resin at two different thicknesses (6 mm diameter and 2 mm thick or 4 mm thick, n = 20) were prepared. The specimens were s...

متن کامل

Effect of Curing Time on Polymerization Rate of Bulk-Fill Composite Resins

Objectives: The aim of this study was to compare polymerization depth of two bulk-fill and one conventional composite cured for different times. Methods: This in vitro experimental study was conducted on 54 composite samples (2×4×10mm) fabricated of Tetric N-Ceram bulk-fill, x-tra fil bulk-fill, and Grandio conventional composite cured for 20, 30, and 40 seconds. The microhardnes...

متن کامل

Effects of 0.2% Chlorhexidine and Re-polishing on the Color Stability of Nanofilled Composite Resins

Introduction: The growing demand for esthetic dental procedures has resulted in the increased development of new restorative composite resins. The success of composite resin restorations depends on their color stability over time. The present study aimed to evaluate the effects of 0.2% chlorhexidine (CHX) and re-polishing on the color stability of nanofilled composite re...

متن کامل

Effects of Polishing Procedures on Color Stability of Composite Resins

The purpose of this study was to investigate the effect of different polishing methods on color stability of posterior, universal and nanohybrid composite resin restorative materials upon exposure to a staining agent. Twenty-five specimens were prepared for each of 5 different composite resins (Filtek Z250, Filtek P60, Quadrant LC, Grandio and Filtek Supreme). Specimens were divided into 5 grou...

متن کامل

Color stability, gloss, and surface roughness of indirect composite resins.

This in vitro study evaluated the color stability, gloss, and surface roughness (Ra) of four indirect composites. Enamel and dentin shades of Radica, Sculpture Plus, Belleglass-NG, and Gradia Indirect were evaluated for color stability. Specimens were stored in a staining solution (coffee) and assessed every 3 days for a period of 21 days, after which color difference (∆E*) was calculated. Only...