the sensitivity and specificity of automated auditory brainstem response and otoacoustic emission in neonatal hearing screening: a systematic review

نویسندگان

saeed heidari health sciences education development department, school of public health, tehran university of medical sciences, tehran, iran

alireza olyaee manesh health financing system, national institute for health research, tehran university of medical sciences, tehran, iran

fatemeh rajabi center for academic and health policy, tehran university of medical sciences, tehran, iran

چکیده

background and aim: otoacoustic emissions (oae) and automated auditory brainstem response (aabr) are the most commonly-used methods for universal neonatal hearing screening (unhs). various sensitivity and specificity rates have been reported for the oae and aabr tests as tools for screening newborn hearing. the main objective of this review was to determine the pooled sensitivity and pooled specificity of each of the two devices in comparison with abr as the gold standard. methods: a systematic review was performed to evaluate the diagnostic accuracy of the oae and aabr tests. research was conducted in the relevant domestic and international databases. there were no time restrictions. the quality of included studies was evaluated with quality assessment of diagnostic accuracy study (quadas) checklist using the software revman 5.1 and results were extracted. after organizing and extracting data, the pooled sensitivity and specificity of oae and aabr tests were calculated with meta-disc software. results: a total of 5154 articles were found; 57 articles were investigated in full and 17 articles possessed the inclusion criteria. analysis was performed on the basis of these results. the quality of the studies was weak (7 cases) to moderate (10 cases). results of the meta-analysis showed that the pooled sensitivity and specificity of the oae were 0.77 and 0.93 respectively, and for aabr they were 0.93 and 0.97 respectively. conclusion: the single stage screening protocol using aabr is an effective alternative to the single stage screening protocol using oae, which is less accurate.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The sensitivity and specificity of automated auditory brainstem response and otoacoustic emission in neonatal hearing screening: a systematic review

Background and Aim: Otoacoustic emissions (OAE) and automated auditory brainstem response (AABR) are the most commonly-used methods for universal neonatal hearing screening (UNHS). Various sensitivity and specificity rates have been reported for the OAE and AABR tests as tools for screening newborn hearing. The main objective of this review was to determine the pooled sensitivity and pooled spe...

متن کامل

Sensitivity of the Automated Auditory Brainstem Response in Neonatal Hearing Screening.

BACKGROUND In a 2-stage neonatal hearing screening protocol, if an infant fails the first-stage abstract screening with an otoacoustic emissions test, an automated auditory brainstem response (ABR)test is performed. The purpose of this study was to estimate the rate of hearing loss detected byfirst-stage otoacoustic emissions test but missed by second-stage automated ABR testing. METHODS The ...

متن کامل

hearing status in neonatal hyperbilirubinemia by auditory brain stem evoked response and transient evoked otoacoustic emission

hyperbilirubinemia at neonatal period is one of the major deteriorating factors of the auditory system. if left untreated, it may cause certain cerebral damage. this study aims to evaluate the impact of hyperbilirubinemia on the hearing of neonate. this study was conducted on 35 newborn babies with jaundice (bilirubin more than 20 mg/dl). auditory brainstem response (abr) and transient evoked o...

متن کامل

Sensitivity and specificity of portable transient otoacoustic emission (TEOAE) in newborn hearing screening.

Early identification and management of hearing impairment is very valuable. The goal standard measurement of hearing loss is by brainstem evoked response (BSER). This prospective study was conducted in Hospital University Kebangsaan Malaysia (HUKM) to determine the sensitivity and specificity of transient evoked otoacoustic emission (TEOAE) as a screening tool for hearing impairment from Februa...

متن کامل

A multisite study to examine the efficacy of the otoacoustic emission/automated auditory brainstem response newborn hearing screening protocol: introduction and overview of the study.

PURPOSE This article is the 1st in a series of 4 articles on a recently completed multistate study of newborn hearing screening. METHOD The study examined the efficacy of the 2-stage otoacoustic emission/automated auditory brainstem response (OAE/A-ABR) protocol for identifying hearing loss in newborns. RESULTS The study found that the 2-stage OAE/A-ABR protocol did miss a significant numbe...

متن کامل

A multisite study to examine the efficacy of the otoacoustic emission/automated auditory brainstem response newborn hearing screening protocol: research design and results of the study.

PURPOSE Most newborns are screened for hearing loss, and many hospitals use a 2-stage protocol in which all infants are screened first with otoacoustic emissions (OAEs). In this protocol, no additional testing is done for those passing the OAE screening, but infants failing the OAE are also screened with automated auditory brainstem response (A-ABR). This study evaluated how many infants who fa...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
auditory and vestibular research

جلد ۲۴، شماره ۳، صفحات ۱۴۱-۱۵۱

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023