the safety of nasal allergen challenge test assessed in lower airways

نویسندگان

edyta krzych-falta unit of environmental hazard prevention and allergology, faculty of health science, medical university of warsaw, warsaw, poland

barbara piekarska unit of environmental hazard prevention and allergology, faculty of health science, medical university of warsaw, warsaw, poland

adam sybilski unit of environmental hazard prevention and allergology, faculty of health science, medical university of warsaw, warsaw, poland and department of pediatrics and neonatology; central clinical hospital of the ministry of interior in warsaw, warsaw, poland

oksana wojas unit of environmental hazard prevention and allergology, faculty of health science, medical university of warsaw, warsaw, poland

چکیده

the aim of the study was to assess the safety of nasal allergen challenge, and the use of certain parameters applied in assessing the condition of the respiratory system. we enrolled 30 patients diagnosed with allergy to common environmental allergens and 30 healthy controls. the safety of nasal challenge tests with an allergen was assessed by measuring the concentration of exhaled nitric oxide from the lower respiratory tract (eno) and forced expiratory volume in one second (fev1) in a spirometry test. in the early phase of the allergic reaction, extra-nasal symptoms were observed, namely cough and breathlessness. these measured symptoms using the vas scale, were far more frequent in the patients diagnosed with perennial allergic rhinitis. the eno and fev1 values in the spirometry test did not show any statistically significant changes. no correlation was observed between the breathlessness and cough complaints to the eno concentration levels (cough: r=0.019, p=0.921; breathlessness: r=-0.088, p=0.644) nor the fev1 level (cough: r=0.002, p=0.983; breathlessness: r=-0.072, p=0.751) in the spirometry test. in the early phase of the allergic reaction, nasal allergen challenge do not cause any significant changes in the lower airways, as measured with the use of certain parameters applied in assessing the function of the lower airways’ function.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Omalizumab inhibits allergen challenge-induced nasal response.

Elevated serum levels of antigen-specific immunoglobulin (Ig)E are often associated with allergic respiratory diseases. This parallel-group, randomised, double-blind, placebo-controlled trial was designed to study the influence of omalizumab on the early nasal response to allergen challenge reflected by symptom score and inflammatory marker levels in nasal lavage fluid (NAL). A total of 23 pati...

متن کامل

Nasal nitric oxide measurements in the assessment of nasal allergen challenge.

BACKGROUND Several objective methods are used to assess the result of nasal allergen challenge. OBJECTIVE The aim of this study was to compare the diagnostic value of nasal nitric oxide (nNO) measurements with that of peak nasal inspiratory flow (PNIF), nasal lavage fluid beta-tryptase levels, and changes in cell count after nasal challenge with grass pollen. METHODS The study population co...

متن کامل

the test for adverse selection in life insurance market: the case of mellat insurance company

انتخاب نامساعد یکی از مشکلات اساسی در صنعت بیمه است. که ابتدا در سال 1960، توسط روتشیلد واستیگلیتز مورد بحث ومطالعه قرار گرفت ازآن موقع تاکنون بسیاری از پژوهشگران مدل های مختلفی را برای تجزیه و تحلیل تقاضا برای صنعت بیمه عمر که تماما ناشی از عدم قطعیت در این صنعت میباشد انجام داده اند .وهدف از آن پیدا کردن شرایطی است که تحت آن شرایط انتخاب یا کنار گذاشتن یک بیمه گزار به نفع و یا زیان شرکت بیمه ...

15 صفحه اول

Efficacy Of Three Thixotropic Nasal Spray Preparations On Seasonal Allergic Rhinitis Assessed By Allergen Challenge In An Environmental Exposure Unit

Two studies were undertaken to assess the efficacy and safety of three thixotropic nasal sprays (IQM11, IQM12, IQM13) on seasonal allergic rhinitis (SAR). The three nasal sprays differ only with respect to the emulsifying agent used in the formulation. In the prospective, randomized, cross-over pilot study, 16 patients with a history of SAR received 2 x 0.14 ml IQM11 per nostril or no treatment...

متن کامل

Nasal challenge test in the diagnosis of allergic respiratory diseases in subjects occupationally exposed to a high molecular allergen (flour).

The objective of this study was the evaluation of the usefulness of the nasal challenge test in the diagnosis of allergic respiratory diseases in subjects occupationally exposed to flour. A single-blind, placebo controlled study was conducted in 100 subjects with occupational atopic asthma with rhinitis. The control groups consisted of 20 atopic subjects not sensitized to investigated allergens...

متن کامل

Dynamics of IL-4 and IL-13 expression in the airways of sheep following allergen challenge

BACKGROUND IL-4 and IL-13 play a critical yet poorly understood role in orchestrating the recruitment and activation of effector cells of the asthmatic response and driving the pathophysiology of allergic asthma. The house dust mite (HDM) sheep asthma model displays many features of the human condition and is an ideal model to further elucidate the involvement of these critical Th2 cytokines. W...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of allergy, asthma and immunology

جلد ۱۴، شماره ۶، صفحات ۵۸۱-۵۸۸

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023