coupling of molecular imprinted polymer nanoparticles by high performance liquid chromatography as an efficient technique for sensitive and selective trace determination of 4-chloro-2-methylphenoxy acetic acid in complex matrices.

نویسندگان

fariborz omidi 1. dept. of occupational health engineering, school of public health, shahroud university of medical sciences , shahroud, iran.

mohammad behbahani 2. dept. of chemistry, faculty of science, shahid beheshti university, g.c. , tehran, iran.

saadi samadi 2. dept. of chemistry, faculty of science, shahid beheshti university, g.c. , tehran, iran.

alireza sedighi 3. dept. of occupational health, school of public health, tehran university of medical sciences , tehran, iran.

چکیده

4-chloro-2-methylphenoxy acetic acid (mcpa) is one of the most important pesticides which is extensively used to control weeds in arable farmland. exposure to this compound occurs in general population and persons who occupationally handle it. the aim of this present work was the preparation of mcpa imprinting polymer and its application as a selective sample preparation technique for trace determination of mcpa in biological and environmental samples.in this study, mcpa imprinting polymer was obtained by precipitation polymerization using methacrylic acid (the functional monomer), ethylene glycol dimethacrylate (the cross-linker), 2, 2'-azobisisobutyronitrile (the initiator) and mcpa (the template molecule) in acetonitrile solution. the mip-nps were characterized by thermogravimetric analysis and scanning electron microscopy. the optimization process was carried out applying batch method. after optimization of the parameters, affecting the adsorption and desorption of analyte, urine and different water samples were used to determine mcpa.imprinted mcpa molecules were removed from the polymeric structure using acetic acid in methanol (20:80 v/v %) as the eluting solvent. both sorption and desorption process occur within 10 min. the maximum sorbent capacity of the molecular imprinted polymer is 87.4 mg g-1. the relative standard deviation and limit of detection for water samples by introduced selective solid phase extraction were 4.8% and 0.9 μg l-1, and these data for urine samples were 4.5% and 1.60 μg l-1, respectively.the developed method was successfully applied to determine mcpa in urine and different water samples.

Sign up for free to access the full text

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coupling of Molecular Imprinted Polymer Nanoparticles by High Performance Liquid Chromatography as an Efficient Technique for Sensitive and Selective Trace Determination of 4-Chloro-2-Methylphenoxy Acetic Acid in Complex Matrices

BACKGROUND 4-chloro-2-methylphenoxy acetic acid (MCPA) is one of the most important pesticides which is extensively used to control weeds in arable farmland. Exposure to this compound occurs in general population and persons who occupationally handle it. The aim of this present work was the preparation of MCPA imprinting polymer and its application as a selective sample preparation technique fo...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

determination of gamma - aminobutyric acid by high-performance liquid chromatography

gamma-aminobutyric acid is the main inhibitory amino acid neurotransmitter in several areas of the brain. measurement of gamma-aminobutyric acid in the brain will help elucidate its metabolic rote and diagnostic value. the liquid chromatography (lc) system consisted of a delivery pump. male rats (150-250g) were used in this study. the brain was rapidly removed from decapitated animals. trie chr...

متن کامل

Application and Optimization of Dispersive Liquid-liquid Microextraction Coupled with High-performance Liquid Chromatography for Sensitive Determination of Furfural and Hydroxymethyl Furfural in Jarred and Canned Baby-foods

Background and Objectives: Furfural (F) and hydroxymethyl furfural (HMF) are cyclic aldehydes, which are formed during the heat processing of foods. These chemical contaminants have received much attention due to their suspected health hazards and heat damage indicators. The aim of the present study was extraction and determination of F and HMF in baby-foods using dispersive liquid-liquid micro...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of public health

جلد ۴۳، شماره ۵، صفحات ۶۴۵-۵۷

کلمات کلیدی
[ 4 , ' c h l o r o ' , 2 , ' m e t h y l p h e n o x y a c e t i c a c i d ' , ' m o l e c u l a r i m p r i n t e d p o l y m e r n a n o p a r t i c l e s ' , ' s e l e c t i v e p r e c o n c e n t r a t i o n ' , ' u r i n e a n d w a t e r s a m p l e s . ' ]

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023