the efficacy of residual chlorine content on the control of legionella spp. in hospital water systems.

نویسندگان

mohammad rafiee 1. dept. of environmental health engineering, alborz university of medical sciences , karaj, iran.

alireza mesdaghinia 2. dept. of environmental health engineering, school of public health, tehran university of medical sciences , tehran, iran.

homa hajjaran 3. dept. of parasitology and mycology, school of public health, tehran university of medical sciences , tehran, iran.

mohammad hajaghazadeh 4. dept. of occupational health, health faculty, urmia university of medical sciences , urmia, iran.

چکیده

outbreaks of legionellosis may be a side effect of institution-water treatment. however, the long-term outcomes and the predictive factors of legionella prevalence in such systems have still not been fully studied. this study was therefore conducted to investigate the prevalence of legionella spp. and to evaluate the role of bacteriological water quality parameters on its prevalence and removal in hospital water systems.a total of 45 samples were collected from distinct sites at seven hospitals in tehran, iran. the prevalence of this bacterium was assayed through a sensitive and specific technique for dna detection using pcr. multivariable stepwise regression analysis was used to explore the independent effects of the baseline factors on the incidence of legionella. two positive samples were also identified for species by dna sequencing.legionella were detected in 31.1% of samples. showerheads and cold-water taps were the most and the least contaminated sources with 55.3 and 9 percent positive samples, respectively. total mean of residual chlorine was 0.38 mg/l, with the peak value of 1.7 mg/l. legionella detection was proportional to the residual chlorine content of water and the results indicated that residual chlorine content is a critical factor in the incidence and proliferation of legionella (r=-0.33). the prevalence of legionella also coincided with the prevalence of hpc and amoeba cysts.the high positive rate of legionella colonization shows that hospital-acquired legionellosis might be under diagnosed in studied hospitals. further, legionella colonization is independent of the type of water, system characteristics and of preventive maintenance measures.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Efficacy of Residual Chlorine Content on the Control of Legionella Spp. In Hospital Water Systems

BACKGROUND Outbreaks of legionellosis may be a side effect of institution-water treatment. However, the long-term outcomes and the predictive factors of Legionella prevalence in such systems have still not been fully studied. This study was therefore conducted to investigate the prevalence of Legionella spp. and to evaluate the role of bacteriological water quality parameters on its prevalence ...

متن کامل

the washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests

در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است

15 صفحه اول

the effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)

cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...

the effect of e-64 on the developmental competence of sheep cocs during in vitro maturation

in the present study, the effect of e-64 at different concentrations (0.5, 1, 5 and 10 µm) added to (1) the ivm medium on oocyte nuclear maturation and developmental competence of ovine oocytes, and (2) to the ivc medium on embryonic development of ovine embryos were investigated.

Legionella control by chlorine dioxide in hospital water systems

egionnaires’ disease is caused by Legionella bacteria, which colonize 12–70% of hospital water systems (Lin et al, 1998b). Of the Legionnaires’ disease cases reported to the Centers for Disease Control and Prevention (CDC), 25–45% were hospital-acquired (Benin et al, 2002). Legionella and other opportunistic pathogens colonize water systems; cause pneumonia, wound, and bloodstream infections in...

متن کامل

the effect of learning strategies on the speaking ability of iranian students in the context of language institutes

the effect of learning strategies on the speaking ability of iranian students in the context of language institutes abstract language learning strategies are of the most important factors that help language learners to learn a foreign language and how they can deal with the four language skills specifically speaking skill effectively. acknowledging the great impact of learning strategies...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of public health

جلد ۴۳، شماره ۵، صفحات ۶۳۷-۴۴

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023