electrochemical sensor based on multiwall carbon nanotube-paste electrode for determination of promethazine in pharmaceutical formulations and blood plasma
نویسندگان
چکیده
a multi-walled carbon nanotube modified paste electrode (mwcn-pe) was used for determination of promethazine (pmz) in drug formulations and blood plasma by cyclic voltammetry (cv) and differential pulse voltammetry (dpv) methods. results revealed that the mwcn-pe shows an electrocatalytic activity toward the anodic oxidation of pmz by a marked enhancement in the current response in buffered solution at ph 5.0. at the mwcn/cpe, the anodic peak potential of pmz was shifted by 28.0 mv to more negative potential in comparison with bare carbon paste electrode. the detection limit for this method was 0.025 µmol l-1. results indicated that the modified electrode could be employed for the determination of promethazine hydrochloride in pharmaceutical formulations and plasma samples.
منابع مشابه
Electrochemical Sensor for Determination of Ascorbic Acid Using a 2-Chlorobenzoyl Ferrocene/Carbon Nanotube Paste Electrode
A chemically modified carbon paste electrode with 2-chlorobenzoyl ferrocene (2CBF) and carbon nanotube (2CBFCNPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, square wave voltammetry and chronoamperometry. The diffusion coefficient (D = 1.42 × 10-6 cm2 s-1), and the kinetic parameter such as ...
متن کاملelectrochemical sensor for determination of ascorbic acid using a 2-chlorobenzoyl ferrocene/carbon nanotube paste electrode
a chemically modified carbon paste electrode with 2-chlorobenzoyl ferrocene (2cbf) and carbon nanotube (2cbfcnpe) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, square wave voltammetry and chronoamperometry. the diffusion coefficient (d = 1.42 × 10-6 cm2 s-1), and the kinetic parameter such as the catalytic rate constant (k = ...
متن کاملElectrochemical Sensor for the Determination of Alizarin Red-S at Non-ionic Surfactant Modified Carbon Nanotube Paste Electrode
The Cyclic Voltammetric (CV) behavior of Alizarin Red-S (ARS), which is an Anthraquinone dye was examined by utilizing TX-100 modified carbon nanotube paste electrode (TX-100MCNTPE). The surfactant utilized is TX-100, and it has been found that it has good electrocatalytic activity towards ARS. Distinctive parameters like pH, scan rate, detection limit have been studied in the potential range o...
متن کاملA New Electrochemical Sensor for Determination of Zolpidem by Carbon Paste Electrode Modified with SnS@SnO2NP
Zolpidem is a drug that is easily attached to the GABA receptors in the brain. This property makes it very effective for tranquilizing as well as hypnagogia. According to the advantages of electrochemical analysis like high selectivity, high sensitivity, low concentration of analyte, cost-effective, portable and easy-to-use setup, they gained high amount of attention among scientists for determ...
متن کاملapplication and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples
ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...
15 صفحه اولDetermination of ascorbic acid by a modified multiwall carbon nanotube paste electrode using cetrimonium iodide/iodine
A new modified graphite-multiwall carbon nanotube paste electrode for the determination of ascorbic acid (AA) based on cetrimonium iodide-iodine is described. The electrochemical response characteristics of the modified electrode toward AA were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in phosphate buffer solution (pH 2.0). When compared to activated carbo...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of advanced medical sciences and applied technologiesجلد ۱، شماره ۱، صفحات ۶۱-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023