numerical analysis of using hybrid photovoltaic-thermal solar water heater in iran

نویسندگان

مسعود محمدی ساردوئی

حمید مرتضی پور

کاظم جعفری نعیمی

چکیده

introduction electrical performance of solar cells decreases with increasing cell temperature, basically because of growth of the internal charge carrier recombination rates, caused by increased carrier concentrations. hybrid photovoltaic/thermal (pvt) systems produce electrical and thermal energy simultaneously. pvt solar collectors convert the heat generated in the solar cells to low temperature useful heat energy and so they provide a lower working temperature for solar cells which subsequently leads to a higher electrical efficiency. recently, in iran, the reforming government policy in subsidy and increasing fossil fuels price led to growing an interest in use of renewable energies for residual and industrial applications. in spite of this, the pv power generator investment is not economically feasible, so far. hybrid pvt devices are well known as an alternative method to improve energy performance and therefore economic feasibility of the conventional pv systems. the aim of this study is to investigate the performance of a pvt solar water heater in four different cities of iran using trnsys program. materials and methods the designed pvt solar water system consists of two separate water flow circuits namely closed cycle and open circuit. the closed cycle circuit was comprised of a solar pvt collector (with nominal power of 880 w and area of 5.6 m2), a heat exchanger in the tank (with volume of 300 l), a pump and connecting pipes. the water stream in the collector absorbs the heat accumulated in the solar cells and delivers it to the water in the tank though the heat exchanger. an on/off controller system was used to activate the pump when the collector outlet temperature was higher than that of the tank in the closed cycle circuit. the water in the open circuit, comes from city water at low temperature, enters in the lower part of the storage tank where the heat transfer occurs between the two separate circuits. an auxiliary heater, connected to the tank outlet, rises the fluid temperature to the set point. the performance of the designed system has been investigated in different cities (including tabriz, tehran, kerman and bandar-abbas) during 4 seasons of year using transient system simulation (trnsys) program. the performance parameters included electrical and thermal energy generation and solar fraction. solar fraction, which expresses the share of energy supplied by solar radiation on the collector in total thermal energy consumption, was obtained from equation 1. results and discussion the results showed that the average daily electricity generation in the cities for summer and winter were 4.65 and 2.67 kwh day-1, respectively. the annual electricity generation of the designed system is almost constant in the various cities. in winter, in spite of lower solar intensity and sunny hours, lower average temperature of solar cells in kerman leads to a slightly better electrical performance than bandar-abbas. the highest cell temperatures, in bandar-abbas between 12 noon and 1pm, were found to be 33, 37, 31 and 25 oc in spring, summer, autumn and winter, respectively. thermal energy generation was significantly different at various cities and seasons. in winter, the designed system provides a little fraction (below 10 percent) of thermal demands in tabriz and tehran. this is mainly because of the low ambient temperature and solar intensity. the pvt system had a maximum average thermal energy of 16 kwh day-1 and solar fraction of 0.5 which were observed in bandar-abbas. tabriz, because of the lowest ambient temperature, had the least thermal energy generation and solar fraction. the maximum average solar fraction obtained in summer was about 60% while its lowest value in winter was 24%. conclusions in the present study, a hybrid pvt solar water heater with nominal power of 880 w was proposed for application in iran. the system was comprised of a pvt solar water collector, an auxiliary heater, a pump and connecting tubes. technical feasibility of applying the proposed system in different cities was investigated using trnsys program. the results are summarized as follows: the annual electricity generation of the designed system was almost constant in the various cities. the highest and lowest values of average electricity generation in summer and winter were determined to be 4.65 and 2.67 kwh day-1, respectively. the pvt system had the maximum average thermal energy of 16 kwh day-1 and solar fraction of 50%, which was observed in bandar-abbas.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Analysis of Solar Water Heater Using Pulsating Heat Pipe

Solar energy is used for solar water heater in domestic and industrial purpose. Pulsating heat pipe is a fast responding, flexible and high performance thermal conducting device. The CLPHP system described in this study relies on the natural forces of gravity and capillary action and does not require an external power source. The flat plate collector consisted of a 2 mm thick sheet of Aluminum ...

متن کامل

Thermodynamic performance analysis of a hybrid Photovoltaic-Thermal (PV/T) integrated greenhouse air heater and dryer

In this paper, performance analysis of a hybrid photovoltaic-thermal (PV/T) greenhouse air heater and dryer has been carried out. Analytical expressions have been developed for • greenhouse air temperature, instantaneous and overall energy and exergy efficiencies for without load and • instantaneous exergy efficiency with load under forced mode operation. An experimental validation has been car...

متن کامل

performance analysis of a two-way hybrid photovoltaic/thermal solar collector

in this paper, the performance evaluation of a two-way hybrid photovoltaic/thermal (pv/t) solar collector was analytically and experimentally carried out. mathematical expressions for operating parameters in glass to glass and glass to tedlar pv/t solar collectors were developed and experimentally validated by a glass to tedlar pv/t solar collector system. also the influence of air flow rate on...

متن کامل

Life Cycle Assessment of solar energy systems: Comparison of photovoltaic and water thermal heater at domestic scale

This study is concerned with the results of a Life Cycle Assessment comparison between photovoltaic e silicon based modules and thin film modules e and solar thermal systems, as technologies which are usually installed for partially covering household energy demand. Several studies focused on energy and environmental performances of photovoltaic and solar thermal collectors, however they have b...

متن کامل

Comprehensive Evaluation of Using Solar Water Heater on a Household Scale in Canada

Canadian researchers are now trying to exploit much more energy from solar sources, hydropower, wind, and biomass. Given the fact that reducing the carbon pollutant level is a political priority in Canada, this paper studies the feasibility of providing sanitary hot water and space heating demands of a four-member family in 10 provinces in this country. The feasibility analysis was performed by...

متن کامل

Thermal Performance of a Double-pass Solar Air Heater

This study analyzes the thermal performance of solar thermal energy using double-pass absorber plate in Sanandaj, Iran. To this end, a mathematical model was encoded according to the energy and exergy balance equations and solved by MATLAB software. Given the environmental conditions and radiation intensity of a winter day in Sanandaj, the effects of external parameters such as radiation intens...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
ماشین های کشاورزی

جلد ۷، شماره ۱، صفحات ۲۲۱-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023