reliability of zebris motion analysis system in healthy athletes and athletes with anterior cruciate ligament reconstruction

نویسندگان

hoda niknam phd candidates, department of physiotherapy, faculty of medical sciences, tarbiat modares university, tehran, iran

ali esteki phd, professor of biomedical engineering, medical physics and biomedical engineering department, school of medicine, shahid beheshti university of medical sciences, tehran, iran; phd, professor of biomedical engineering, medical physics and biomedical engineering department, school of medicine, shahid beheshti university of medical sciences, tehran, iran. tel: +98-2123872566, fax: +98-2122439941

mahyar salavati phd, department of physiotherapy, university of social welfare and rehabilitation sciences, tehran, iran

sedighe kahrizi phd, department of physiotherapy, faculty of medical sciences, tarbiat modares university, tehran, iran

چکیده

conclusions zebris movement analysis system is a highly reliable instrument for the measurement of gait parameters at different speeds in healthy athletes and those after acl reconstruction surgery. this implies its use in the assessment and treatment process of gait deficits in such a clinically important population. background reconstruction surgery is one of the treatment methods after an anterior cruciate ligament (acl) injury especially in athletes. reconstructed acl is associated with altered joint biomechanics, abnormal muscle strength, gait disorder and decreased athletic performance. abnormal walking pattern has been shown to be one of the functional consequences of acl reconstruction. results in the patient group, relative reliability measures for almost all parameters were high at low (icc: 0.7 - 0.97), preferred and high speeds (icc: 0.75 - 0.97). this was also true for the control group, were reliability for all parameters was high at low, preferred (icc: 0.74 - 0.99) and high (icc: 0.83 - 0.99) speeds, except for stride time of the left leg which showed moderate reliability. additionally, at high speed, all parameters revealed very high reliability. methods a sample of convenience including 20 healthy athletes and 20 athletes 4 to 6 months after acl reconstruction participated. subjects walked on a treadmill for one minute at preferred, high and low speeds and kinematic and spatio - temporal parameters including stride time, stride length, maximum knee flexion, maximum knee flexion velocity and maximum knee extension velocity are calculated. objectives the aim of this study was to investigate the reliability of kinematic and spatiotemporal gait parameters after acl reconstruction using zebris ultrasound movement analysis system.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Kinetics of Athletes with Anterior Cruciate Ligament Reconstruction in Neuro-Cognitive Challenge Landing

Neurocognitive motor tasks have been shown to have an effective relationship with athletic performance and musculoskeletal injuries. Cognitive changes following anterior cruciate ligament reconstruction surgery may lead to adverse knee biomechanical changes and an increased risk of secondary injury. This study aimed to compare the kinetics of athletes with a history of ACL reconstruction and th...

متن کامل

Associations between Vitamin D Levels and Risk of Anterior Cruciate Ligament Injury in Male Athletes

Background and purpose: Association between vitamin D and anterior cruciate ligament injury (ACLI) in male athletes is poorly understood, and current data are not sufficient and consistent. The present study investigated the association between vitamin D and ACLI in some Iranian male athletes. Materials and methods: This cross-sectional study was carried out in 100 male athletes with knee pain...

متن کامل

The Prevalence of Neuromuscular Deficiencies Associated With Non-Contact Anterior Cruciate Ligament Injury in Healthy Collegiate Student-Athletes

Background: Identifying lower extremity defects during high impact activity, such as landing, especially in young athletes who play team sports, could help to prevent non-contact lower extremity injuries. The Tuck Jump Assessment (TJA) is a screening instrument designed to recognize neuromuscular deficits related to Anterior Cruciate Ligament (ACL) injury. The current study investigated the pre...

متن کامل

Failure of Anterior Cruciate Ligament Reconstruction

  The present review classifies and describes the multifactorial causes of anterior cruciate ligament (ACL) surgery failure, concentrating on preventing and resolving such situations. The article particularly focuses on those causes that require ACL revision due to recurrent instability, without neglecting those that affect function or produce persistent pain. Although primary ACL reconstructio...

متن کامل

Isokinetic profile in female athletes with and without patellofemoral pain syndrome after anterior cruciate ligament reconstruction.

Anterior Cruciate Ligament (ACL) injury is one of the most frequent injury type in individuals who participate in pivoting sports, with an annual incidence of more than 200,000 cases according to the American Academy of Orthopaedic Surgeons (2007).This has motivated numerous studies on risk factors and prevention strategies (see Griffin et al., 2000 for review), as well as on ACL reconstruction...

متن کامل

Anterior Cruciate Ligament Injury Prevention Training in Female Athletes

CONTEXT Many anterior cruciate ligament (ACL) injury prevention training programs have been published, but few have assessed the effects of training on both ACL injury rates and athletic performance tests. OBJECTIVE To determine if ACL injury prevention programs have a positive influence on both injury rates and athletic performance tests in female athletes. DATA SOURCES In August 2011, a s...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
asian journal of sports medicine

جلد ۸، شماره ۱، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com