an in-house indirect immunofluorescence test for ensuring that the cell bank is contamination free
نویسندگان
چکیده
background: cross-contamination between cells is a usual mistake at cell culture laboratories and cell banks worldwide. mrc5 diploid cell and rk-13, vero and hela continuous cell lines are used in different stages of human viral vaccines propagation at razi vaccine and serum research institute of iran. however diploid and continuous cells are propagated at separated cell culture laboratory and continuous cells can contaminate mrc5 diploid cells. therefore, a sensitive test is needed. world health organization recommends few molecular and cellular techniques to cell characterization. materials and methods: the present study was therefore designed to set up an indirect immunofluorescence (iif) test as follows: polyclonal anti-mrc5 cell and anti-rabbit antibodies were prepared in rabbit and goat, respectability. anti-rabbit igg was purified using protein g affinity chromatography, conjugated to fluorescein isothiocyanate (fitc), and then further purified to remove unbound fitc using sephadex g 25 chromatography. using double immunodiffusion assay, purification of homemade anti-rabbit igg was asssayed by observation of a single arch. results: the titer of homemade fitc conjugated goat anti rabbit igg was measured 1/16 vs 1/8 of commercial type. fluorescein/protein molar ratio of local made fluorescein goat anti-rabbit igg was measured 3.44 and its protein concentration and fitc concentration were determined 1.198 mg/ml and 0.01 mg/ml, respectively. conclusion: moreover, homemade iif test showed 100% intra-laboratory reproducibility. purity of three batches of mrc5 working seed cell was verified using in- house iif test and no contamination to continuous cell lines was found . k e y w o r ds: mrc-5, cross-contamination, indirect immunofluorescence technique, quality control test, human viral vaccine
منابع مشابه
Development of Indirect Immunofluorescence Technique for the Identification of MRC5 Working Seed Cell
Diploid and continuous cell lines are used to propagate viral vaccines. At Human Viral Vaccine Department of Razi Vaccine and Serum Research Institute, MRC5 diploid cell is used for the development of live attenuated measles, mumps, rubella, and three types of poliovirus vaccines. Additionally, three continuous cell lines (i.e., RK13, HeLa, and Vero) are applied in quality control tests. Accor...
متن کاملIndirect immunofluorescence test for the detection of Aspergillus fumigatus antibodies.
An indirect immunofluorescence test was both sensitive and specific in detecting IgG antibodies to Aspergillus fumigatus. The test revealed a significant increase in titre of antibodies in patients with the allergic or mycetomal forms of pulmonary aspergillosis.
متن کاملthe test for adverse selection in life insurance market: the case of mellat insurance company
انتخاب نامساعد یکی از مشکلات اساسی در صنعت بیمه است. که ابتدا در سال 1960، توسط روتشیلد واستیگلیتز مورد بحث ومطالعه قرار گرفت ازآن موقع تاکنون بسیاری از پژوهشگران مدل های مختلفی را برای تجزیه و تحلیل تقاضا برای صنعت بیمه عمر که تماما ناشی از عدم قطعیت در این صنعت میباشد انجام داده اند .وهدف از آن پیدا کردن شرایطی است که تحت آن شرایط انتخاب یا کنار گذاشتن یک بیمه گزار به نفع و یا زیان شرکت بیمه ...
15 صفحه اولA Comparative Study of an Elisa Test and an Indirect Immunofluorescence Test for Serological Diagnosis of Babesia Bovis Infection
A COMPARATIVE STUDY OF AN ELISA TEST AND AN INDIRECT IMMUNOFLUORESCENCE TEST FOR SEROLOGICAL DIAGNOSIS OF BABESIA BOVIS INFECTION. Detection of antibodies to Babesia bovis in cattle is essential for the understanding of the epidemiology of babesiosis and this study was concerned with comparing the indirect fluorescent antibody with the ELISA. Both assays gave rise to 100% sensitivity whilst the...
متن کاملDetection of antigonococcal IgA in cervical secretions by indirect immunofluorescence: an evaluation as a diagnostic test.
Using an indirect immunofluorescent-antibody method, antigonococcal IgA was detected in the cervical secretions of 56 (72%) of 78 women with untreated gonorrhoea but in only 25 (5%) of 490 non-infected women. The low sensitivity--comparable to that of Gram-stain microscopy--the expense, and the laboriousness of the test militate against its use as a routine diagnostic procedure.
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
archives of medical laboratory sciencesجلد ۱، شماره ۳، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023