determination of reducing sugar in potato using a manual glucose determiner and comparing with enzymatic procedure
نویسندگان
چکیده
in order to estimate the reducing sugar in tubers of potato by using a manual glucose determiner, an experiment was conducted in factorial arrangement based on completely randomized design with three replications. in this research reducing sugar of four cultivars of potato – agria, sante, with two methods: enzymatic and a manual glucose determiner. the results picaso and kizer – that maintained in two temperatures of germinator, 3 and 7.5ºc, were measured indicated that there was no significant difference between determinated glucose by using a manual glucose determiner and enzymatic procedure, but there was a significant difference between determinated glucose by using a manual glucose determiner and total reducing sugar measured by enzymatic procedure. the effect of maintenance conditions on glucose content and total reducing sugar in both procedures was significant and treatments that were maintained at higher temperatures had less sugar. the effect of cultivar on glucose content and total reducing sugar in both procedures was significant and in temperature 3ºc, agria and sante had the highest sugar content, but in temperature 7.5ºc, there was no significant difference among reducing sugar content of four cultivars.
منابع مشابه
development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
Determination of glucose by an improved enzymatic procedure.
The glucoseoxidase-peroxidasesystem for the enzymatic determination of glucose was investigated with respect to the instability of the enzyme reagent, the buffering capacity of the reaction milieu, and the stability and sensitivity of the final chromogen. An improved procedure was developed in which the enzyme solution is both stabilized and more adequately buffered by reconstitution in 40% aqu...
متن کاملDetermination of glucose in biologic fluids with an automated enzymatic procedure.
An automated procedure for the enzymatic determination of “true” glucose with the glucose oxidase-peroxidase system is described. A threefold increase in sensitivity was obtained through meaurement of the stable, pink chromogen obtained at high acid concentration. Good reproducibility and stoichiometry was obtained over the range of 50-400 mg./l00 ml. at a sampling rate of 40/hr. The normal ran...
متن کاملa comparison of teachers and supervisors, with respect to teacher efficacy and reflection
supervisors play an undeniable role in training teachers, before starting their professional experience by preparing them, at the initial years of their teaching by checking their work within the proper framework, and later on during their teaching by assessing their progress. but surprisingly, exploring their attributes, professional demands, and qualifications has remained a neglected theme i...
15 صفحه اولa study on rate making and required reserves determination in reinsurance market: a simulation
reinsurance is widely recognized as an important instrument in the capital management of an insurance company as well as its risk management tool. this thesis is intended to determine premium rates for different types of reinsurance policies. also, given the fact that the reinsurance coverage of every company depends upon its reserves, so different types of reserves and the method of their calc...
Electrochemical-Enzymatic Determination of Glucose in Beverages
This laboratory seeks to quantitatively determine glucose concentration in common beverages. The method employed is enzyme catalyzed oxidation of glucose, quantified by chronoamperometry. With an inexpensive patterned electrode and low cost glucose oxidase enzyme, an electrochemical sensor is constructed to selectively measure glucose in complicated beverages which can present as analytically c...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
پژوهش های علوم و صنایع غذایی ایرانجلد ۷، شماره ۴، صفحات ۰-۰
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023