improvement of left ventricular assist device (lvad) in artificial heart using particle swarm optimization

نویسندگان

majid neshat yazdi

reihaneh kardehi moghaddam

چکیده

in this approach, the left ventricular assist pump for patients with left ventricular failure isused. the failure of the left ventricle is the most common heart disease during these days. inthis article, a state feedback controller method is used to optimize the efficiency of a samplingpump current. particle swarm algorithm, which is a set of rules to update the position andvelocity, is applied to find the optimal state feedback controller parameters for the first time.in comparison to other optimization algorithms, including genetic algorithm, pso has higherconvergence speed. as it is shown in the simulation part in the same number of iterations, thepso algorithm decreases the cost function, which leads to desired transient and stabilityresponse of the system more effectively. in addition, in this work we propose a new structurefor the cost function which includes the dynamical equations of current sampling pump incombination with penalty sentences which decrease the speed and output fluctuations. in thisarticle, the system model and the system controlling parameters are set in such a way that theproposed cost function can be optimized. the efficiency of the method is illustrated insimulation part.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Stroke and Left Ventricular Assist Device (LVAD)

Treatment of ischemic stroke for a patient on left ventricular assist device (LVAD) by neurointerventional means is rare and many anesthesia providers are unfamiliar with both LVAD and neurointerventional protocols. Examples of this include: 1) filling for continuous-flow LVAD depend on preload and the flow is inversely related to afterload; as mean arterial pressure (MAP) increases above 80 to...

متن کامل

LVAD: Left ventricular assist devices for end-stage heart failure.

Heart failure affects more than 5 million Americans with approximately 200,000 patients in end-stage disease that has failed traditional treatment. Historically, the only option for treatment was a heart transplant until left ventricular assist devices offered another option.

متن کامل

Left Ventricular Heart Assist Device using MC and ECG Feedback

The human heart pumps blood throughout the body via the circulatory system, supplying oxygen and nutrients to the tissues which helps bodies function and removing carbon dioxide and other waste products [1]. Cardiac failure happens when the heart cannot pump enough blood and oxygen to support other organs [2]. In USA about 5.7 million adult patients are diagnosed with heart failure and one in 9...

متن کامل

A Rare Cause of Left Ventricular Assist Device (LVAD) Obstruction: Left Atrial Dissection

Left atrial dissection is a rare factor that may cause left ventricular assist device obstruction. Prompt diagnosis and surgical repair are essential. This case report describes our experience and a successful surgical management in a patient after HeartMate 3 implantation and mitral valve inflow obstruction due to a left atrial dissection.

متن کامل

Heart monitoring using left ventricle impedance and ventricular electrocardiography in left ventricular assist device patients

BACKGROUND Patients who develop critical arrhythmia during left ventricular assist device (LVAD) perfusion have a low survival rate. For diagnosis of unexpected heart abnormalities, new heart-monitoring methods are required for patients supported by LVAD perfusion. Ventricular electrocardiography using electrodes implanted in the ventricle to detect heart contractions is unsuitable if the heart...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of artificial intelligence in electrical engineering

ناشر: ahar branch,islamic azad university, ahar,iran

ISSN 2345-4652

دوره 1

شماره 4 2013

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023