transcatheter closure of patent ductus arteriosus using the amplatzer ductal occluder: early results and midterm follow-up

نویسندگان

mostafa behjati ardakani afshar hospital, yazd university of medical sciences, yazd, iran.

sayed khalil forouzannia afshar hospital, yazd university of medical sciences, yazd, iran.

majid dehghani afshar hospital, yazd university of medical sciences, yazd, iran.

mohammad hassan abdollahi afshar hospital, yazd university of medical sciences, yazd, iran.

چکیده

background: the transcatheter closure of patent ductus arteriosus has advanced rapidly with improvements in device designs. the aim of this study was to analyze the safety, efficacy, and early and intermediate follow-up results of the percutaneous closure of persistent ductus arteriosus (pda) with the amplatzer ductal occluder (ado) in children.   methods: between may 2004 and march 2007, fifty patients between 7 months and 20 years of age underwent the transcatheter closure of pda, using the ado. the mean pda diameter at its narrowest segment (pulmonary end) was 7.35±2.57 mm (range: 4 to 16mm). follow-up evaluations were performed via echocardiography at 24 hours, and 1, 3, 6, and 12 months and then yearly after implantation. results: successful immediate occlusion of pda was achieved in 42 (84%) of the 50 cases.   in 5 cases, there were trivial intraprosthetic residual shunts. in addition, there was a small residual shunt in one case, left pulmonary artery narrowing in one case, and embolization of the device immediately after the procedure in one case. at 24 hours, color doppler flow mapping revealed complete closure in all except one case with a small shunt. at 3 months’ follow-up, occlusion was complete in all the patients. at a median follow-up of 17 months (range: 3 months to 32 months), all the patients had complete closure. conclusion : we conclude that although the transcatheter closure of pda using the ado is a highly effective and safe treatment for most patients, several complications including embolization and left pulmonary artery narrowing may occur in certain cases.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Closure of Large Patent Ductus Arteriosus Using the Amplatzer Ductal Occluder

Background: Coils are suitable for the closure of a small patent ductus arteriosus (PDA) but are not recommended for a large PDA. We reported our initial experience of transcatheter closure of a large PDA using the Amplatzer ductal occluder (ADO). Methods: From April 2002 to October 2006, all patients with ductal size greater than 3.5 mm undergoing transcatheter closure of PDA using the ADO wer...

متن کامل

[Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder: initial results and mid-term follow-up].

INTRODUCTION AND OBJECTIVES Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and mid-term results of the treatment of PDA with the Amplatzer duct occluder. PATIENTS AND METHODS From October 1999 to December 2001, 30 children underwent transcatheter closure of persistent ductus arteriosus at a mean SD age of 5 4....

متن کامل

Transcatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder: Initial Results and Mid-Term Follow-Up

Received 11 March 2002. Accepted for publication 28 May 2002. Introduction and objectives. Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and midterm results of the treatment of PDA with the Amplatzer duct occluder. Patients and methods. From October 1999 to December 2001, 30 children underwent transcatheter clo...

متن کامل

Long-Term Results of Transcatheter Closure of Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder

OBJECTIVE Patent ductus arteriosus (PDA) is one of the most frequently seen congenital heart diseases. Its closure is recommended because of the risk of infective endocardis, as well as morbidity and mortality in the long. The aim of this study was to assess the long term results of the transcatheter closure of PDA in infants using amplatzer duct occlude (ADO). METHODS From May 2004 to Septem...

متن کامل

long-term follow-up of patent ductus arteriosus closure with the amplatzer duct occluder in children

background: t ranscatheter closure of patent ductus arteriosus (pda) has become an alternative treatment to surgery. we evaluated the long-term results of the transcatheter closure of pda with the amplatzer duct occluder (ado) in children. methods: between may 2004 and october 2012, 138 children with pda (43 males and 95 females) underwent transcatheter pda closure. clinical, electrocardiograph...

متن کامل

Transcatheter closure of large sized patent ductus arteriosus using the amplatzer duct occluder device.

OBJECTIVE To assess the results of anterograde transcatheter closure of a large sized patent ductus arteriosus using the Amplatzer Duct Occluder (ADO) device. STUDY DESIGN A case series. PLACE AND DURATION OF STUDY Department of Cardiology, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from January 2005 to December 2007. METHODOLOGY All patient...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
the journal of tehran university heart center

جلد ۳، شماره ۳، صفحات ۱۵۱-۱۵۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023