signal-averaged electrocardiography in patients with advanced heart failure: a better indicator of left ventricular enlargement compared with conventional electrocardiography
نویسندگان
چکیده
background : the signal-averaged electrocardiography is a noninvasive method to evaluate the presence of the potentials generated by tissues activated later than their usual timing in the cardiac cycle. the purpose of this study was to demonstrate the correlation between the filtered qrs duration obtained via the signal-averaged electrocardiography and left ventricular dimensions and volumes and then to compare it with the standard electrocardiography. methods : we included patients with advanced systolic left ventricular dysfunction (ejection fraction ≤ 35%). all the patients underwent surface twelve-lead electrocardiography, signal-averaged electrocardiography, and echocardiography. results : the study included 86 patients with a mean age of 54.66 ± 13.23 years. the mean left ventricular ejection fraction was 18.31 ± 5.49%; the mean qrs duration was 0.14 ± 0.02 sec; and 52% of the patients had left bundle branch block. the mean filtered qrs duration was 145.87 ± 24.89 ms. our data showed a significant linear relation between the filtered qrs duration and left ventricular end-systolic volume, left ventricular end-diastolic volume, left ventricular end-systolic diameter, and left ventricular end-diastolic diameter; the correlation coefficient was, however, not good. there was no significant correlation between the qrs duration and left ventricular diameters and volumes. conclusion : the filtered qrs duration has a better correlation with left ventricular dimensions and volumes than does the qrs duration in the standard electrocardiography.
منابع مشابه
Signal-Averaged Electrocardiography in Patients with Advanced Heart Failure: A Better Indicator of Left Ventricular Enlargement Compared with Conventional Electrocardiography
BACKGROUND The signal-averaged electrocardiography is a noninvasive method to evaluate the presence of the potentials generated by tissues activated later than their usual timing in the cardiac cycle. The purpose of this study was to demonstrate the correlation between the filtered QRS duration obtained via the signal-averaged electrocardiography and left ventricular dimensions and volumes and ...
متن کاملSignificance of Signal Averaged Electrocardiography in Patients with Advanced Heart Failure and Intraventricular Conduction Delay
AIMS Signal averaged electrocardiography is a noninvasive method to evaluate the presence of the potentials that are generated by tissues, activated later than their usual timing in the cardiac cycle. The purpose of this study was to demonstrate the correlation of data obtained via signal averaged electrocardiography and left ventricular dyssynchrony. METHODS We included the patients with adv...
متن کاملElectrocardiography Findings in Children with Epilepsy Compared with Healthy Children
Background Epilepsy is one of the most common neurological diseases. Over the last decades the hypothesis of cardiovascular effects from sudden seizure has been raised, and cardiac rhythm and ECG changes in these patients have been highlighted. The study aimed to evalua...
متن کاملDetermination of left ventricular mass in systemic hypertension: comparison of standard and signal averaged electrocardiography.
OBJECTIVE To investigate the quantitative relationship, if any, between signal averaged electrocardiographic variables and echocardiographically determined left ventricular mass in hypertensive subjects. DESIGN Cohort analytic prospective study. SETTING University hospital. SUBJECTS 50 hypertensive subjects selected consecutively from inpatients. Patients older than 75 years, with underly...
متن کاملUncertainty principle of signal-averaged electrocardiography.
BACKGROUND Signal-averaged ECG (SAECG) reproducibility is reported to have a component that is independent of residual noise. Methods and Results-In group 1, multiple paired SAECGs were obtained to noise levels of 0.3+/-0.1 and 0.5+/-0.2 microV. For the 0.5- and 0. 3-microV noise recordings, QRS duration (QRSd) was 101.2+/-11.3 and 104.6+/-9.6 ms, respectively (P<0.0001), and the differences in...
متن کاملSignal averaged electrocardiography and renal function in hypertensive patients
Abnormal signal averaged electrocardiograms (SAECGs) and late ventricular potentials (LVPs) are predictors of sudden cardiac death. The present study hypothesized that SAECGs are impaired in hypertensive patients with renal failure. A total of 30 patients with grade 2 hypertension underwent SAECG. Serum level of creatinine and glomerular filtration rate (GFR) were also assessed. At least one SA...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
the journal of tehran university heart centerجلد ۶، شماره ۲، صفحات ۶۸-۷۱
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023