characterization of suitability of coronary venous anatomy for targeting left ventricular lead placement in patients undergoing cardiac resynchronization therapy
نویسندگان
چکیده
background: differences in the quantity and distribution of coronary veins between patients with ischemic and non-ischemic cardiomyopathy might affect the potential for the left ventricular (lv) lead targeting in patients undergoing cardiac resynchronization therapy (crt). in the current study, we assessed and compared the suitability of the coronary venous system for the lv lead placement in ischemic and dilated cardiomyopathy. methods: this single-centre study, performed at our hospital, retrospectively studied 173 patients with the new york heart association class iii or iv who underwent crt. the study population was comprised of 74 patients with an ischemic underlying etiology and 99 patients with a non-ischemic etiology. the distribution of the veins as well as the final lead positions was recorded. results: there was no significant difference between the two groups in terms of the position of the available suitable vein with the exception of the posterior position, where the ischemic group had slightly more suitable veins than did the dilated group (48.4% versus 32.1%, p value = 0.049). there was also no significant difference with respect to the final vein, through which the lv lead was inserted. comparative analysis showed that the patients with previous coronary artery bypass grafting surgery (cabg) had significantly fewer suitable veins in the posterolateral position than did the non-cabg group (16.3% versus 38.7%, p value = 0.029). there was, however, no significant difference between the two subgroups regarding the final vein position in which the leads were inserted. conclusion: the final coronary vein position suitable and selected for the lv lead insertion was not different between the cases with cardiomyopathy with different etiologies, and nor was it different between the ischemic cases with and without a history of cabg. patients with a history of procedures around the coronary vessel may have an intact or recovered venous system and may, therefore, benefit from transvenous lv lead placement for crt.
منابع مشابه
Characterization of Suitability of Coronary Venous Anatomy for Targeting Left Ventricular Lead Placement in Patients Undergoing Cardiac Resynchronization Therapy
BACKGROUND Differences in the quantity and distribution of coronary veins between patients with ischemic and nonischemic cardiomyopathy might affect the potential for the left ventricular (LV) lead targeting in patients undergoing cardiac resynchronization therapy (CRT). In the current study, we assessed and compared the suitability of the coronary venous system for the LV lead placement in isc...
متن کاملComprehensive use of cardiac computed tomography to guide left ventricular lead placement in cardiac resynchronization therapy
BACKGROUND Optimal lead positioning is an important determinant of cardiac resynchronization therapy (CRT) response. OBJECTIVE The purpose of this study was to evaluate cardiac computed tomography (CT) selection of the optimal epicardial vein for left ventricular (LV) lead placement by targeting regions of late mechanical activation and avoiding myocardial scar. METHODS Eighteen patients un...
متن کاملSnare system for left ventricular lead placement in cardiac resynchronization therapy.
A 79-year-old man, previously diagnosed with ischemic heart disease and valve disease, who had undergone coronary artery bypass grafting and aortic valve replacement, was referred for implantation of a cardiac resynchronization system with defibrillator (CRT-D). He was in NYHA functional class III under optimized medical therapy, with left ventricular ejection fraction of 25%, mean QRS of 160 m...
متن کاملThoracoscopic Left Ventricular Lead Implantation in Cardiac Resynchronization Therapy
Cardiac resynchronization therapy is known to reduce morbidity and mortality in patients with advanced heart failure as a result of dyssynchrony and systolic dysfunction of the left ventricle. Placement of the left ventricular (LV) lead via the coronary sinus can be difficult. When LV lead implantation is difficult, a video-assisted epicardial approach can be a good alternative. Although there ...
متن کاملImpacted left ventricular lead technique in cardiac resynchronization therapy.
Left ventricular (LV) lead dislodgement is a significant problem in cardiac resynchronization therapy and re-operation is required to rectify the situation. In this case report, we describe a new technique to stabilize an LV lead which is prone to dislodgement by impacting an inactive LV lead in the same cardiac vein.
متن کاملRelation of left ventricular lead placement in cardiac resynchronization therapy to left ventricular reverse remodeling and to diastolic dyssynchrony.
The effects of left ventricular (LV) lead placement for cardiac resynchronization therapy (CRT) on LV remodeling and dyssynchrony are not well defined. Sixty-one patients (age 60 +/- 11 years, 76% men) were evaluated by echocardiography before and 4 +/- 2 months after CRT and grouped by the LV lead placement (lateral, posterolateral, or anterolateral). Echocardiographic measurements included LV...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
the journal of tehran university heart centerجلد ۷، شماره ۱، صفحات ۱۰-۱۴
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023