late development of a bronchocutaneous fistula due to an epicardial cardioverter-defibrillator lead
نویسندگان
چکیده
cutaneous complications caused by a pacemaker or defibrillator are widely documented, but the development of a bronchocutaneous fistula has never been described before. we report the case of a 79-year-old man who was admitted to our hospital because of a seemingly superficial cutaneous infection, externalized defibrillator leads, and hemoptysis. bronchoscopical investigation proved the existence of the fistula, which connected the epicardium, the left main bronchus, and the aforementioned site of skin infection. the patient refused an operation for the complete removal of the epicardial defibrillator and was treated conservatively. this case demonstrated that the long-term presence of foreign bodies in the epicardium may cause serious complications
منابع مشابه
Late Development of a Bronchocutaneous Fistula due to an Epicardial Cardioverter-Defibrillator Lead
Cutaneous complications caused by a pacemaker or defibrillator are widely documented, but the development of a bronchocutaneous fistula has never been described before. We report the case of a 79-year-old man who was admitted to our hospital because of a seemingly superficial cutaneous infection, externalized defibrillator leads, and hemoptysis. Bronchoscopical investigation proved the existenc...
متن کاملImplantable cardioverter-defibrillator lead performance.
Implantable cardioverter-defibrillators (ICDs) have revolutionized the treatment of patients at risk for sudden cardiac death. In the nearly 3 decades since the first human ICD implant,1 millions of devices have been implanted worldwide and innumerable lives have been saved. Successful resuscitation of a potentially lethal ventricular arrhythmia by an ICD system depends on successful arrhythmia...
متن کاملVery late perforation of an implantable cardioverter defibrillator lead: a case report.
British Journal of General Practice, February 2014 107 IntroduCtIon Every year approximately 40 000 pacemakers and defibrillators are implanted in the UK amounting to one new implanted device per GP.1 Placements of pacemakers or implantable cardioverter defibrillators (ICDs) have become routine procedures and are generally associated with low complication rates. One of the most endangering comp...
متن کاملAn algorithm to predict implantable cardioverter-defibrillator lead failure.
OBJECTIVES The goal of this analysis was to test an algorithm that identifies implantable cardioverter-defibrillator (ICD) lead problems before clinical failure and/or inappropriate therapy. BACKGROUND The ICD lead failures typically present as inappropriate shock therapy. Identifying lead failures before their clinical presentation may prevent patient discomfort, improve device longevity, an...
متن کاملHigh failure rate for an epicardial implantable cardioverter-defibrillator lead: implications for long-term follow-up of patients with an implantable cardioverter-defibrillator.
OBJECTIVES The purpose of this study was to determine the risk of epicardial lead failure during long-term follow-up and its mode of presentation. BACKGROUND Despite the high prevalence of epicardial lead-based implantable cardioverter-defibrillators, their long-term performance is unknown, and appropriate follow-up has not been established. METHODS The study group comprised all patients in...
متن کاملThe formation of bronchocutaneous fistulae due to retained epicardial pacing wires: A literature review
Temporary epicardial pacing wires during open-heart surgery are routinely used both for diagnostic and treatment purposes. In complicated cases where patients are unstable or the wires are difficult to remove, the pacing wires are cut at the skin level and allowed to retract by themselves. This procedure rarely causes complications. However, there have been cases reporting that retained pacing ...