introduction: the main purpose of this study was to compare transient ischemic dilation (tid) ratios in spect-low dose ct and spect myocardial perfusion imaging (mpi) by application of different quantitative programs and quantify the possible shift in the upper normal limits of tid ratio in the spect-ct mpi. methods: 149 patients with low pre-test probability for coronary artery disease (cad), based upon diamond and forrester method entered the study. each patient underwent both attenuation correction (ac) spect-ct mpi and non attenuation correction (nac) spect mpi (two day tc-99m sestamibi stress-rest protocol). normalcy rates were also calculated and compared. the comparison was based on both visual interpretation and quantitative analysis. results: in the low pre-test probability group visual interpretations lead to a statistically significant improvement in normalcy rate in the spect-ct acquisition compared to the spect mpi. regardless of the stress type and software programs used, no significant difference was noted in the upper normal limits of the tid ratios between the ac and nac acquisitions. conclusion: the study showed superiority of spect-ct mpi to spect mpi in terms of normalcy rate. we also propose new upper normal limits of tid ratios for different sets of acquisition-gender-stress modality-software programs.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD), ...

متن کامل

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Transient Ischemic Dilatation Ratio in Stress Myocardial Perfusion SPECT in Diabetic Patients-A Systematic Review and Meta-Analysis

Abstract Objective: Abnormal values of the transient ischemic dilation (TID) ratio are associated with severe and extensive coronary artery disease (CAD). TID can be used as a diagnostic and prognostic marker of CAD in diabetic patients. The aim of current study was to determine the pooled estimate of TID ratio in single myocardial perfusion scan in diabetic patients by a systematic review and...

متن کامل

Filter selection for 99mTc-Sestamibi myocardial perfusion SPECT imaging [Persian]

Myocardial perfusion SPECT imaging with Tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. Though simple and straight forward the results produced by the technique is very much affected by the details being used. One of the main problems with the test, wh...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of nuclear medicine

ناشر: tehran university of medical sciences

ISSN 1681-2824

دوره 22

شماره 2 2014

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023