evaluation of attenuation correction process in cardiac spect images
نویسندگان
چکیده
introduction: attenuation correction is a useful process for improving myocardial perfusion spect and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). attenuation artifacts are a common problem in myocardial perfusion spect. the aim of this study was to compare the effect of attenuation correction using different attenuation maps and different activities in a specially designed heart phantom. methods: the spect imaging for different activities and different body contours were performed by a phantom using tissue-equivalent boluses for making different thicknesses. the activity was ranged from 0.3-2mci and the images were acquired in 180 degree, 32 steps. the images were reconstructed by osem method in a pc computer using matlab software. attenuation map were derived from ct images of the phantom. two quality and quantity indices, derived from universal image quality index have been used to investigate the effect of attenuation correction in each spect image.results: the result of our measurements showed that the quantity index of corrected image was in the range of 3.5 to 5.2 for minimum and maximum tissue thickness and was independent of activity. comparing attenuation corrected and uncorrected images, the quality index of corrected image improved by increasing body thickness and decreasing activity of the voxels. conclusion: attenuation correction was more effective for images with low activity or phantoms with more thickness. in our study, the location of the pixel relative to the associated attenuator tissues was another important factor in attenuation correction. the more accurate the registration process (attenuation map and spect) the better the result of attenuation correction.
منابع مشابه
Evaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کاملThe influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کاملNew approach for attenuation correction in SPECT images, using linear optimization
Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...
متن کاملInfluences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom
Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...
متن کاملBreath-hold CT attenuation correction for quantitative cardiac SPECT
BACKGROUND Attenuation correction of a single photon emission computed tomography (SPECT) image is possible using computed tomography (CT)-based attenuation maps with hybrid SPECT/CT. CT attenuation maps acquired during breath holding can be misaligned with SPECT, generating artifacts in the reconstructed images. The purpose of this study was to investigate the effects of respiratory phase duri...
متن کاملnew approach for attenuation correction in spect images, using linear optimization
background: photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of spect images and results to errors in accuracy of quantitative measurements. this can be corrected via different physical or mathematical approaches. as the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘piece wise line...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of nuclear medicineناشر: tehran university of medical sciences
ISSN 1681-2824
دوره 16
شماره 2 2008
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023