advanced motion correction methods in pet
نویسندگان
چکیده
with the arrival of increasingly higher resolution pet systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. in this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. for the first type of motion (most often studies in pet brain imaging), conventional motion-correction algorithms have relied on extraction of the motion information from the emission data itself. however, the accuracy of motion compensation in this approach is degraded by the noisy nature of the emission data. subsequently, advanced methods, as reviewed in this work, make use of external real-time measurements of motion. various image-based and projection-based correction methods have been discussed and compared. the paper also reviews recent and novel applications that perform corrections for cardiac and respiratory motions. unlike conventional gating schemes, in which the cardiac and respiratory gated frames are independently reconstructed (resulting in noisy images), the reviewed methods are seen to follow a common trend of seeking to produce images of higher quality by making collective use of all the gated frames (and the estimated motion). as an observation, a general theme in motion-correction methods is seen to be the use of increasingly sophisticated software to make use of existing advanced hardware. in this sense, this field is very open to future novel ideas (hardware, and especially software) aimed at improving motion detection, characterization and compensation.
منابع مشابه
Advanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملAdvanced Motion Correction Methods in PET ( Review Article )
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of motion...
متن کاملPractical PET Respiratory Motion Correction in Clinical PET/MR.
UNLABELLED Respiratory motion during PET acquisition may lead to blurring in resulting images and underestimation of uptake parameters. The advent of integrated PET/MR scanners allows us to exploit the integration of modalities, using high spatial resolution and high-contrast MR images to monitor and correct PET images degraded by motion. We proposed a practical, anatomy-independent MR-based co...
متن کاملMotion correction strategies for integrated PET/MR.
UNLABELLED Integrated whole-body PET/MR facilitates the implementation of a broad variety of respiratory motion correction strategies, taking advantage of the strengths of both modalities. The goal of this study was the quantitative evaluation with clinical data of different MR- and PET-data-based motion correction strategies for integrated PET/MR. METHODS The PET and MR data of 20 patients w...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملPET motion correction using MR-derived motion parameters
Medical Imaging Research Center, Department of Nuclear Medicine, KU Leuven, Belgium With the improving resolution of modern PET scanners, any slight motion during the scan can cause significant blurring and loss of resolution. MRI scanners have the capacity to perform quick successive scans and thus provide a means to track motion during a scan. Hence, with the advent of simultaneous PET-MR sca...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of nuclear medicineناشر: tehran university of medical sciences
ISSN 1681-2824
دوره 13
شماره 2 2005
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023