diagnostic accuracy of a portable sleep apnea screener against standard polysomnography in patients referred to a sleep laboratory
نویسندگان
چکیده
background and objective: obstructive sleep apnea (osa) is a disease with serious consequences. many portable devices have been developed to overwhelm some of limitations in the accessibility of the gold standard test for osa, polysomnography (psg). this study aimed to determine diagnostic accuracy of a portable sleep apnea screener against psg in patients of a sleep clinic. materials and methods: patients admitted to a sleep lab were recruited during a three-month period. study participants underwent one night simultaneous recording of psg and a double channel portable sleep apnea screener in the laboratory. a sleep physician scored the psgs manually according to standard criteria. portable sleep apnea screener data were analyzed automatically with the manufacturer’s proprietary software. we com- pared the apnea–hypopnea indices (ahi) from the psg and the portable sleep apnea screener to assess the spec- ificity and sensitivity of the device. results: a total of 120 patients completed the study. mean ahi recorded from psg and portable device were 31.7 and 30.8, respectively. using a variety of ahi cutoff values (5, 10, 15, 20, 30 and 40), sensitivities of the portable device were 96.9, 88.6, 87.2, 84.1, 79.6, and 83.9 percent and specificities were 45.5, 71.9, 69.0,74.5, 90.1, and 88.8 percent, respectively. the lrs+ were 1.77, 3.15, 2.81, 3.29, 8.04 and 7.49 and the lrs- were 0.06, 0.15, 0.18, 0.21, 0.22 and 0.18. the aucs were 0.90, 0.88, 0.86, 0.89, 0.90, and 0.92, respectively. conclusions: in studied participants, portable device showed acceptable sensitivity and specificity in the lab when compared to the standard psg.
منابع مشابه
Diagnostic Accuracy of a Portable Sleep Apnea Screener against Standard Polysomnography in Patients Referred to a Sleep Laboratory
Background and Objective: Obstructive sleep apnea (OSA) is a disease with serious consequences. Many portable devices have been developed to overwhelm some of limitations in the accessibility of the gold standard test for OSA, polysomnography (PSG). This study aimed to determine diagnostic accuracy of a portable sleep apnea screener against PSG in patients of a sleep clinic. Materials and Metho...
متن کاملAssociation of irritable bowel syndrome and sleep apnea in patients referred to sleep laboratory
BACKGROUND Irritable bowel syndrome (IBS) is assumed as one of the most frequent gastrointestinal disorders, which decreases the patient's quality of life. IBS pathogenesis, however, is not clearly defined. It seems that sleep apnea induces or escalates IBS clinical symptoms. This study aims at evaluating of IBS prevalence in patients, who are afflicted or are not afflicted with sleep apnea. ...
متن کاملGender and age differences in polysomnography findings and sleep complaints of patients referred to a sleep laboratory.
Our objective was to examine the effet of gender on the sleep pattern of patients referred to a sleep laboratory. The data (questionnaires and polysomnographic recordings) were collected from a total of 2365 patients (1550 men and 815 women). The polysomnography permits an objective assessment of the sleep pattern. We included only polysomnography exams obtained with no more than one recording ...
متن کاملEvaluation of the accuracy of SNAP technology sleep sonography in detecting obstructive sleep apnea in adults compared to standard polysomnography.
OBJECTIVE To determine the accuracy of snoring and apnea analysis by SNAP (SNAP Laboratories; Glenview, IL), a technology that uses snoring recorded by a home microphone system and nasal airflow, to diagnose obstructive sleep apnea (OSA) as well as determine its severity. METHODS For all patients who had undergone a prior SNAP study and were referred to the Sleep Disorders Center of Lifespan ...
متن کاملFactors predictive of obstructive sleep apnea in patients undergoing pre-operative evaluation for bariatric surgery and referred to a sleep laboratory for polysomnography
OBJECTIVE To identify the main predictive factors for obtaining a diagnosis of obstructive sleep apnea (OSA) in patients awaiting bariatric surgery. METHODS Retrospective study of consecutive patients undergoing pre-operative evaluation for bariatric surgery and referred for in-laboratory polysomnography. Eight variables were evaluated: sex, age, neck circumference (NC), BMI, Epworth Sleepine...
متن کاملobstructive sleep apnea syndrome in children referred to a sleep clinic
background and objective: failure in diagnosis and treatment of sleep apnea in children lead to physical and mental growth retardation, cardiopulmonary, and/or behavioral disorders. this study was aimed to evaluate polysomnographic (psg) and clinical findings of sleep apnea in children referred to a sleep clinic in qazvin, iran. materials and methods: this cross-sectional study was conducted am...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of sleep sciencesجلد ۱، شماره ۱، صفحات ۲-۷
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023