modeling and experimental study of carbon dioxide absorption in a flat sheet membrane contactor
نویسندگان
چکیده
comin the present study, co2 removal from natural gas stream has been studied using a flat sheet membrane contactor. a three dimensional mathematical model is developed to describe the process. the model considers the transport of a gas mixture containing carbon dioxide and methane through a flat sheet membrane contactor module. the model is based on the non-wetted mode of operation, in which the gas fills the membrane pores in a countercurrent gas-liquid contact. simulation was performed using computational fluid dynamics (cfd) of the model material and momentum transport equations in the flat sheet membrane for laminar flow conditions. physical and chemical absorptions were considered in the simulations for the absorption of co2 in aqueous sodium hydroxide solution. simulation predictions were in good agreement with the experimental data for different values of gas flow rates. the modeling predictions indicate that the removal of co2 increased with increasing inlet liquid flow rate and increasing solvent temperature, by contrast, increase in inlet gas flow rate has negative effect.
منابع مشابه
Modeling and Experimental Study of Carbon Dioxide Absorption in a Flat Sheet Membrane Contactor
comIn the present study, CO2 removal from natural gas stream has been studied using a flat sheet membrane contactor. A three dimensional mathematical model is developed to describe the process. The model considers the transport of a gas mixture containing carbon dioxide and methane through a flat sheet membrane contactor module. The model is based on the non-wetted mode of operation, in which t...
متن کاملAmine Based CO2 Absorption in Membrane Contactor Using Polyvinyl Pyrrolidone-modified Polysulfone Flat Sheet Membrane: Experimental Study and Mass Transfer Resistance Analysis
Membrane contactor using amine based absorbents is an efficient technology for CO2 separation from gaseous mixtures. A novel porous polysulfone (PSF) flat membrane was prepared via non-solvent phase inversion method. The PSF membrane was modified by adding polyvinyl pyrrolidone (PVP) to the dope solution. The fabricated membrane was used in the serpentine flow field contactor module for CO2 abs...
متن کاملSeparation and Fixation of Carbon Dioxide Using Polymeric Membrane Contactor
Polypropylene hollow fiber membrane (PPHFM) contactor, with aqueous solution absorbent such as sodium hydroxide (NaOH), monoethanolamine (MEA) and diethanolamine (DEA), was designed and used to separate and fix CO2 from CO2/N2 gas mixtures. The factors that influence the separation properties of CO2/N2 were investigated. It was found that the CO2 removal efficiency is the best by using MEA solu...
متن کاملEffect of Different Additives on Separation Performance of Flat Sheet PVDF Membrane Contactor
This paper investigates effects of different additives on morphology and subsequently, separation performance of asymmetric flat sheet Polyvinylidene fluoride (PVDF) membranes to separate CO2 using membrane contractor. Five different additives from different chemical families including Lithium chloride (salt), Polyethylene glycol 400 (polymer), glycerol (weak anti-solvents), methanol...
متن کاملComputational Fluid Dynamics Simulation Study of a Novel Membrane Contactor for Simultaneous Carbon Dioxide Absorption and Stripping
Physical absorption is a potential technology for economic carbon capture due to its low energy consumption, however, the absorption efficiency of current systems must be improved. In this study, novel hybrid absorption/stripping membrane contactors (HASMCs) for physical solvent carbon capture are proposed. The simultaneous absorption and stripping within one module provides instant regeneratio...
متن کاملFabrication and Characterization of Polyetherimide Hollow Fiber Membrane Contactor for Carbon Dioxide Stripping from Monoethanolamine Solution
In this research, process asymmetric polyetherimide hollow fiber membranes using ethanol (0, 2 and 4 wt%) as non-solvent additive in the polymer dope via phase inversion method were fabricated. Aqueous solution of 1-methyl-2-pyrrolidine (NMP) (90%) was applied as a bore fluid to avoid inner skin layer formation and water was used as the external coagulant. The morphology of fabricated membranes...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of membrane science and researchجلد ۳، شماره ۲، صفحات ۵۷-۶۳
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023