highly selective and sensitive sensor based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane as a heterocyclic ionophore

نویسندگان

fariba mehranfar

department of chemistry, ahvaz branch, islamic azad university, ahvaz, iran arezoo ghaemi

department of chemistry, ahvaz branch, islamic azad university, ahvaz, iran haman tavakkoli

department of chemistry, ahvaz branch, islamic azad university, ahvaz, iran

چکیده

a new polyvinyl choloride (pvc) membrane sensor for cerium (iii) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22dd) as an ionophore. the sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1m, with a nernstian slope of 18.0±1.0 mv/decade, and a detection limit of 9.7×10-7m. it has a fast response time (5 s) and can be used for two months without any considerable divergence in its potential. the proposed sensor revealed high selectivity toward ce3+ion with respect to some alkali, alkaline earth and transition metal cations. it could be used in a wide ph range of 2.0-11.0. the sensor was successfully used as an indicator electrode in potentiometric titration of ce3+ion with ethylenediaminetetraacetic acid (edta) and sodium iodide (nai) solutions, and in determination of ce (iii) concentration in real samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly selective and sensitive sensor based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane as a heterocyclic ionophore

A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two mont...

متن کامل

A novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples

A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...

متن کامل

PVC based 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane electrode for Cerium (III) ions

A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response tim...

متن کامل

A novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples

A new polyvinyl choloride (PVC) membrane sensor for cerium(III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensorexhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with aNernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two month...

متن کامل

Charge-transfer triiodide ion-selective electrode based on 7,16-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane.

A new PVC membrane electrode for the triiodide ion based on a charge-transfer complex of iodine with 7,16-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as a membrane carrier was prepared. The electrode exhibits a Nernstian response for triiodide ions over a wide concentration range (1.0 x 10(-1)-1.0 x 10(-5) M) with a slope of 59.3 +/- 0.9 mV decade(-1) and a detection limit of 6.3 x 10...

متن کامل

Jgp_201711777 413..416

By tracking conformational transitions of individual ion channel proteins, single-channel recordings allow the observer to deduce gating mechanisms, as well as estimate rate constants of microscopic gating steps. For most ion channels, gating mechanisms are complex, comprising multiple stable open (O) and closed (C) conformations among which conformational transitions may follow a network of po...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of heterocyclic chemistry

جلد ۶، شماره ۱، صفحات ۴۱-۴۹

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023