creep and viscoelastic behaviour of human dentin
نویسندگان
چکیده
statement of problem: biomechanics of the human dentition is inherently complex. purpose: the aim of this study is to investigate, in vitro, the creep and the recovery of dentin under static uniaxial compressive stress conditions. materials and methods: specimens of cylindrical morphology were prepared from recently extracted non-carious lower molar teeth, such that the average tubule orientation was axial. slides of mid- coronal dentin (parallel surfaces, height 1.8 mm) were sectioned with a slow speed diamond saw and then cut into cylindrical discs. specimens were stored at 4ºc for 24h to restabilize water content. creep data were then measured by lvdt axially in water for periods of 2h load + 2h recovery on 4 separate groups (n=6): at two stresses (10 & 18 mpa) and at two temperatures: 37 & 60ºc. maximum creep strain, permanent set, strain recovery and initial compressive modulus were reported. results: compliance values were also calculated and slight non-linearity found at 60ºc. two-way anova was performed on results. dentin exhibited a linear viscoelastic response under 'clinical' compressive stress levels, with a maximum strain ~ 1% and high recoverability: permanent set<0.3%. conclusion: this established a performance standard for viscoelastic stability of restorative biomaterials, replacing human dentin.
منابع مشابه
Creep rupture of viscoelastic fiber bundles.
We study the creep rupture of bundles of viscoelastic fibers occurring under uniaxial constant tensile loading. A fiber bundle model is introduced that combines the viscoelastic constitutive behavior and the strain controlled breaking of fibers. Analytical and numerical calculations showed that above a critical external load the deformation of the system monotonically increases in time resultin...
متن کاملViscoelastic properties of demineralized dentin matrix.
OBJECTIVES To evaluate the viscoelastic properties of demineralized dentin matrix. Stress-relaxation studies were done on matrices in tension and strain elongation or creep studies were done in both tension and compression. METHODS Mid-coronal dentin disks were prepared from extracted unerupted human third molars. Disks were 0.5 mm thick for stress-relaxation or tensile creep experiments and ...
متن کاملElectrostatically Driven Creep in Viscoelastic Dielectric Elastomers
We utilize a nonlinear, dynamic finite element model coupled with a finite deformation viscoelastic constitutive law to study the inhomogeneous deformation and instabilities resulting from the application of a constant voltage to dielectric elastomers. The constant voltage loading is used to study electrostatically driven creep and the resulting electromechanical instabilities for two different...
متن کاملViscoelastic behaviour of pumpkin balloons
The lobes of the NASA ULDB pumpkin-shaped super-pressure balloons are made of a thin polymeric film that shows considerable time-dependent behaviour. A nonlinear viscoelastic model based on experimental measurements has been recently established for this film. This paper presents a simulation of the viscoelastic behaviour of ULDB balloons with the finite element software ABAQUS. First, the stan...
متن کاملThe role of proteoglycans in the nanoindentation creep behavior of human dentin.
Attempts to understand the mechanical behavior of dentin and other mineralized tissues have been primarily focused on the role of their more abundant matrix components, such as collagen and hydroxyapatite. The structural mechanisms endowing these biological materials with outstanding load bearing properties, however, remain elusive to date. Furthermore, while their response to deformation has b...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of dentistry, tehran university of medical sciencesجلد ۱، شماره ۱، صفحات ۵-۱۴
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023