transverse strength of reinforced denture base resin with metal wire and e-glass fibers

نویسندگان

m. vojdani

aar. khaledi

چکیده

statement of problem: fracture strength of a denture base resin is of great concern, and many approaches have been used to strengthen acrylic resin dentures. purpose: the aim of this study was to measure the transverse strength of a heat polymerized acrylic resin, after reinforcement with metal wire and two types of glass fibers. materials and methods: forty rectangular specimens (65.0×10.0×3.3 mm) of a heat- cured acrylic resin were made according to iso/fdi 1567. group i (control group) consisted of 10 specimens with no reinforcement. specimens in group ii reinforced with sandblasted metal wires. group iii and iv strengthened with woven (stick net) and continuous unidirectional (stick) fibers respectively. the specimens were polymerized according to manufacturer’s recommendation. the transverse strengths were assessed with a 3- point bending test at cross head speed of 5mm/min. one-way anova was carried out to compare and detect any differences among groups (=0.05). results: mean transverse strength (sd) of unreinforced specimens was 85.44 (8.6) mpa. the transverse strength increased significantly to 97.97 (5.5) mpa, 109.69 (5.8) mpa, and 127.13 (6.4) mpa in metal wires, stick net, and stick fibers groups, respectively. conclusion: the transverse strength of heat-polymerized denture base resin was enhanced considerably by using metal wire and glass fibers reinforcements. however, the addition of unidirectional glass fibers was significantly more effective method to improve flexural strength of denture base acrylic resin.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transverse Strength of Reinforced Denture Base Resin with Metal Wire and E-Glass Fibers

Statement of problem: Fracture strength of a denture base resin is of great concern, and many approaches have been used to strengthen acrylic resin dentures. Purpose: The aim of this study was to measure the transverse strength of a heat polymerized acrylic resin, after reinforcement with metal wire and two types of glass fibers. Materials and Methods: Forty rectangular specimens (65.0×10.0×3.3...

متن کامل

Color change in acrylic denture base resin reinforced with wire mesh and glass cloth.

In this study, the L*a*b* color system as a color system and light transmittance of the denture base resin reinforced with wire mesh and glass cloth were measured, and the color difference (deltaE*ab) was calculated using L*, a* and b* values which were measured both on a white calibration plate and on a null background. The thicknesses of test specimens, which were reinforced with wire mesh an...

متن کامل

transverse strength of repaired denture base material with wire and two auto polymerized acrylic resin

objective: the purpose of this study was to evaluate the transverse strength of one brand of denture base material repaired with two autopolymerized acrylic resins with and without wire reinforcement. materials and methods: eighty samples (2.5×10×65 mm3) were fabricated and divided into five groups. the control group was left intact. groups b and d specimens were repaired with autopolymerizing ...

متن کامل

Transverse Strength of Repaired Denture Base Material with Wire and Two Auto Polymerized Acrylic Resin

Received: 15 October 2006 Accepted: 16 May 2007 Abstract: Objective: The purpose of this study was to evaluate the transverse strength of one brand of denture base material repaired with two autopolymerized acrylic resins with and without wire reinforcement. Materials and Methods: Eighty samples (2.5×10×65 mm) were fabricated and divided into five groups. The control group was left intact. Grou...

متن کامل

Flexural strength of heat-polymerized polymethyl methacrylate denture resin reinforced with glass, aramid, or nylon fibers.

STATEMENT OF PROBLEM Despite the favorable properties of conventional PMMA used as a denture base material, its fracture resistance could be improved. PURPOSE This in vitro study was performed to determine whether the flexural strength of a commercially available, heat-polymerized acrylic denture base material could be improved through reinforcement with 3 types of fibers. MATERIAL AND METH...

متن کامل

Effect of Water Storage on the Flexural Strength of Heat-cured Denture Base Resin Reinforced with Stick (s) Glass Fibers

BACKGROUND Flexural strength (FS) of denture base resins (DBRs) had been improved by reinforcing it with different glass fibers. However, a limited data are available on the effect of glass fiber reinforcement with conventional heat-cured resin after prolonged water storage. AIMS AND OBJECTIVES This study aimed to evaluate the reinforcing effect of novel S-glass and nylon fibers on the FS of ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dentistry, tehran university of medical sciences

جلد ۳، شماره ۴، صفحات ۱۵۹-۱۶۶

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023