microtensile bond strength of single bond and adper prompt-l-pop adhesives to dentin
نویسندگان
چکیده
objective: the aim of this study was to evaluate the microtensile bond strength to sound and caries-affected dentin using single bond and adper prompt-l-pop adhesives. materials and methods: sixteen extracted human molars with carious lesions extended halfway through dentin were ground to expose the caries affected and the surrounding normal dentin. the samples were divided into two groups of eight samples each, including single bond (two-step etch and rinse) and adper prompt-l-pop (one step self-etch). z-100 (3m) was used for composite build-ups. the teeth were then sectioned and prepared for micro tensile bond strength test, at cross head speed of 1.5 mm/min. data were ana-lyzed by 1- and 2-way anova. results: bond strengths of single bond and adper prompt-l-pop adhesives to sound den-tin were significantly higher than to the caries-affected one (p<0.001), besides, bond strength of single bond to dentin was generally found to be higher than adper prompt-l-pop adhesive (p<0.001).the interaction effect was not significant (p=0.116) conclusion: bond strength to caries-affected dentin was compromised when one and two step adhesives were used.
منابع مشابه
Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin
Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin Dr. A. Ghasemi* - Dr. M. Bargrizan** - Dr. M. Mahmoodi*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Pedodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. ***...
متن کاملMicrotensile Bond Strength of Self-etching Adhesives to Dentin
The aim of this study was to determine microtensile bond strength of two and one-step self-etching adhesive systems to dentin. 25 intact human third molars were used. Flat surfaces of mid-coronal dentin were exposed and the teeth were divided into 5 groups (n=5). Composite build-ups were made using the following self-etching systems / composite materials: 2-step self-etching system Contax / Ecu...
متن کاملThe Effect of Temperature on Shear Bond Strength of Clearfil SE Bond and Adper Single Bond Adhesive Systems to Dentin
STATEMENT OF THE PROBLEM Monomer viscosity and solvent evaporation can be affected by the adhesive system temperature. Higher temperature can elevate the vapor pressure in solution and penetration of adhesive in smear layer. Bonding mechanism may be influenced by the adhesive temperature. PURPOSE This study aimed to evaluate the effect of pre-heating on shear bond strength of etch-and-rinse a...
متن کاملMicrotensile bond strength and interfacial characterization of 11 contemporary adhesives bonded to bur-cut dentin.
OBJECTIVES This study evaluated mechanically and ultra-morphologically 11 different adhesive systems bonded to dentin. METHODS The microtensile bond strength (microTBS) of 11 contemporary adhesives, including two three-step etch&rinse, three two-step etch&rinse, two two-step self-etch and four one-step self-etch adhesives to dentin, were measured. The resultant interfacial ultra-structure at ...
متن کاملEffects of blood contamination on microtensile bond strength to dentin of three self-etch adhesives.
This study evaluated the effects of blood contamination and decontamination methods during different steps of bonding procedures on the microtensile bond strength of two-step self-etch adhesives to dentin. Sixty extracted human molars were ground flat to expose occlusal dentin. The 60 molars were randomly assigned to three groups, each treated with a different two-step self-etch adhesive: Clear...
متن کاملEffect of Airborne Particle Abrasion on Microtensile Bond Strength of Total-Etch Adhesives to Human Dentin
Aim of this study was to investigate a specific airborne particle abrasion pretreatment on dentin and its effects on microtensile bond strengths of four commercial total-etch adhesives. Midcoronal occlusal dentin of extracted human molars was used. Teeth were randomly assigned to 4 groups according to the adhesive system used: OptiBond FL (FL), OptiBond Solo Plus (SO), Prime & Bond (PB), and Ri...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of dentistry, tehran university of medical sciencesجلد ۵، شماره ۱، صفحات ۱۲-۱۶
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023