the effect of aging on the accuracy of new friction-style mechanical torque limiting devices for dental implants.

نویسندگان

aboulfazl saboury dental research center, research institute of dental sciences of shahid beheshti university of medical sciences, tehran, iran ; associate professor, department of prosthodontics, dental school, shahid beheshti university of medical sciences, tehran, iran.

seyed jalil sadr

ali fayaz

minoo mahshid

چکیده

high variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (f-s mtlds). the effect of aging (number of use) on the accuracy of these devices is not clear. the purpose of this study was to assess the effect of aging on the accuracy (±10% of the target torque) of f-s mtlds.fifteen new f-s mtlds and their appropriate drivers from three different implant manufacturers (astra tech, biohorizon and dr idhe), five for each type, were selected. the procedure of peak torque measurement was performed in ten sequences before and after aging. in each sequence, ten repetitions of peak torque values were registered for the aging procedure. to measure the output of each device, a tohnichi torque gauge was used.before aging, peak torque measurements of all the devices tested in this study falled within 10% of their preset target values. after aging, a significant difference was seen between raw error values of three groups of mtlds (p<0.05). more than 50% of all peak torque measurements demonstrated more than 10% difference from their torque values after aging.within the limitation of this study, aging as an independent factor affects the accuracy of f-s mtlds. astra tech mtlds presented the most consistent torque output for 25 ncm target torque.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Aging on the Accuracy of New Friction-Style Mechanical Torque Limiting Devices for Dental Implants

OBJECTIVE High variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (F-S MTLDs). The effect of aging (number of use) on the accuracy of these devices is not clear. The purpose of this study was to assess the effect of aging on the accuracy (±10% of the target torque) of F-S MTLDs. MATERIALS AND METHODS Fifteen new F-S MTLDs and their ap...

متن کامل

the effect of aging on the accuracy of spring-style mechanical torque limiting devices for dental implants

objective: recently, a wide variation has been reported in delivery of the target torque by spring-style mechanical torque limiting devices (mtlds) but the effect of aging on their accuracy has not been independently evaluated. the purpose of this study was to determine the effect of aging on the accuracy of spring-style mtlds. methods: in this in-vitro experimental study, 15 new spring-style m...

متن کامل

the effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices for dental implants

background: mechanical torque limiting devices (mtlds) are necessary tools to control a peak torque and achieving target values of screw component of dental implants. due to probable effect of autoclaving and number of use on the accuracy of these devices, this study aimed to evaluate the effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devi...

متن کامل

The effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices for dental implants

BACKGROUND Mechanical torque limiting devices (MTLDs) are necessary tools to control a peak torque and achieving target values of screw component of dental implants. Due to probable effect of autoclaving and number of use on the accuracy of these devices, this study aimed to evaluate the effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devic...

متن کامل

evaluation of the accuracy and related factors of the mechanical torque-limiting device for dental implants.

accurate delivery of torque to implant screws is critical to generate ideal preload in the screw joint and to offer protection against screw loosening. mechanical torque-limiting devices (mtlds) are available for this reason. in this study, the accuracy of one type of friction-style and two types of spring-style mtlds at baseline, following fatigue conditions and sterilization processes were de...

متن کامل

modification of nanoclay for improving the physico-mechanical properties of dental adhesives

هدف اصلی این مطالعه تهیه یک سامانه نوین چسب عاجی دندانی بر پایه نانورس پیوند شده با پلی متاکریلیک اسید، نانورس پیوند شده با پلی اکریلیک اسید، مخلوط نانوسیلیکا و نانورس پیوند شده با پلی متاکریلیک اسید، مخلوط نانوسیلیکا و نانورس پیوند شده با پلی اکریلیک اسید و نانورس پیوند شده با کیتوسان اصلاح شده با گلایسیدیل متاکریلات است. پیوند پلی متاکریلیک اسید و پلی اکریلیک اسید بر ری سطح نانورس در حضور و ...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dentistry, tehran university of medical sciences

جلد ۱۰، شماره ۱، صفحات ۴۱-۵۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023