evaluation of the accuracy and related factors of the mechanical torque-limiting device for dental implants.
نویسندگان
چکیده
accurate delivery of torque to implant screws is critical to generate ideal preload in the screw joint and to offer protection against screw loosening. mechanical torque-limiting devices (mtlds) are available for this reason. in this study, the accuracy of one type of friction-style and two types of spring-style mtlds at baseline, following fatigue conditions and sterilization processes were determined.five unused mtlds were selected from each of straumann (iti), astra tech and cwm systems. to measure the output of each mtld, a digital torque gauge with a 3-jaw chuck was used to hold the driver. force was applied to the mtlds until either the friction styles released at a pre-calibrated torque value or the spring styles flexed to a pre-calibrated limit (target torque value). the peak torque value was recorded and the procedure was repeated 5 times for each mtld. then mtlds were subjected to fatigue conditions at 500 and 1000 times and steam sterilization processes at 50 and 100 times and the peak torque value was recorded again at each stage.adjusted difference between measured torque values and target torque values differed significantly between stages for all 3 systems. adjusted difference did not differ significantly between systems at all stages, but differed significantly between two different styles at baseline and 500 times fatigue stages.straumann (iti) devices differed minimally from target torque values at all stages. mtlds with spring-style were significantly more accurate than friction-style device in achieving their target torque values at baseline and 500 times fatigue.
منابع مشابه
Evaluation of the Accuracy and Related Factors of the Mechanical Torque-Limiting Device for Dental Implants
OBJECTIVE Accurate delivery of torque to implant screws is critical to generate ideal preload in the screw joint and to offer protection against screw loosening. Mechanical torque-limiting devices (MTLDs) are available for this reason. In this study, the accuracy of one type of friction-style and two types of spring-style MTLDs at baseline, following fatigue conditions and sterilization process...
متن کاملthe evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology
abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...
15 صفحه اولmodification of nanoclay for improving the physico-mechanical properties of dental adhesives
هدف اصلی این مطالعه تهیه یک سامانه نوین چسب عاجی دندانی بر پایه نانورس پیوند شده با پلی متاکریلیک اسید، نانورس پیوند شده با پلی اکریلیک اسید، مخلوط نانوسیلیکا و نانورس پیوند شده با پلی متاکریلیک اسید، مخلوط نانوسیلیکا و نانورس پیوند شده با پلی اکریلیک اسید و نانورس پیوند شده با کیتوسان اصلاح شده با گلایسیدیل متاکریلات است. پیوند پلی متاکریلیک اسید و پلی اکریلیک اسید بر ری سطح نانورس در حضور و ...
the effect of aging on the accuracy of spring-style mechanical torque limiting devices for dental implants
objective: recently, a wide variation has been reported in delivery of the target torque by spring-style mechanical torque limiting devices (mtlds) but the effect of aging on their accuracy has not been independently evaluated. the purpose of this study was to determine the effect of aging on the accuracy of spring-style mtlds. methods: in this in-vitro experimental study, 15 new spring-style m...
متن کاملthe effect of aging on the accuracy of new friction-style mechanical torque limiting devices for dental implants.
high variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (f-s mtlds). the effect of aging (number of use) on the accuracy of these devices is not clear. the purpose of this study was to assess the effect of aging on the accuracy (±10% of the target torque) of f-s mtlds.fifteen new f-s mtlds and their appropriate drivers from three differ...
متن کاملthe evaluation and comparison of two esp textbooks available on the iranian market for teaching english to the students of medicine
abstract this study evaluated and compared medical terminology and english for the students of medicine (ii) as two representatives of the textbooks available on the iranian market for teaching english to the students of medicine. this research was performed on the basis of a teacher’s and a number of students’ attitudes and the students’ needs analysis for two reasons: first, to investigate...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of dentistry, tehran university of medical sciencesجلد ۱۰، شماره ۲، صفحات ۱۱۲-۸
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023