assessing the amount of interdental bone in posterior areas of the mandible for placing orthodontic mini-implants.

نویسندگان

nasrin esfahanizadeh associated professor, department of periodontics, islamic azad university, dental branch, member of dental implant research center, tehran university of medical sciences, tehran, iran.

damoun shahraki post graduate student, department of orthodontics, islamic azad university, dental branch, tehran, iran.

hamidreza daneshparvar assistant professor, legal medicine research center, tehran, iran.

ahmad reza talaei pour professor and chairman, department of radiology, islamic azad university, dental branch, tehran, iran.

چکیده

objective : the aim of this study was to assess the amount of interdental bone in posterior areas of the mandible for placing orthodontic mini-implants to provide and control anchorage in orthodontic treatment. materials and methods : the amount of interdental bone in areas between the second premolars and first molars, first and second molars on the right and left sides of the mandible were determined in fifty patients by rvg using periapical radiographs. the images were assessed using cygnus media software to determine the mesio-distal width of the interdental bone, starting at the crest of the alveolar bone (2 mm below the cej) every one millimeter up to 12 mm from the cej. the actual amount of interdental bone and the effect of related factors were assessed using chi-square test at a 95% confidence interval. results : the minimum desired interdental bone width for placing mini-implants, 3 mm from the cej, between the second premolar and first molar and the first and second molars of the mandible on both sides were significantly different (p<0.01): 1.8 mm (31%) more apical in the area between the second premolar and the first molar. there was also a statistically significant difference between the areas under study on the right side (p<0.002), which was 2.2 mm (44%) more apical in the area of the second premolar and the first molar. conclusion : the most secure site for placing orthodontic mini-implants in the mandible is between the first and second molars at the height of 5.8 mm from the cej.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing the Amount of Interdental Bone in Posterior Areas of the Mandible for Placing Orthodontic Mini-Implants

Objective : The aim of this study was to assess the amount of interdental bone in posterior areas of the mandible for placing orthodontic mini-implants to provide and control anchorage in orthodontic treatment. Materials and Methods : The amount of interdental bone in areas between the second premolars and first molars, first and second molars on the right and left sides of the mandible were de...

متن کامل

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

romantic education:reading william wordsworths the prelude in the light of the history of ideas

عصر روشنگری زمان شکل گیری ایده های مدرن تربیتی- آموزشی بود اما تاکید بیش از اندازه ی دوشاخه مهم فلسفی زمان یعنی عقل گرایی و حس گرایی بر دقت و وضوح، انسان عصر روشنگری را نسبت به دیگر تواناییهایش نابینا کرده و موجب به وجود آمدن افرادی تک بعدی شد که افتخارعقلانیتشان، تاکید شان بر تجربه فردی، به مبارزه طلبیدن منطق نیاکانشان وافسون زدایی شان از دنیا وتمام آنچه با حواس پنجگانه قابل درک نبوده و یا در ...

the effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)

cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...

the test for adverse selection in life insurance market: the case of mellat insurance company

انتخاب نامساعد یکی از مشکلات اساسی در صنعت بیمه است. که ابتدا در سال 1960، توسط روتشیلد واستیگلیتز مورد بحث ومطالعه قرار گرفت ازآن موقع تاکنون بسیاری از پژوهشگران مدل های مختلفی را برای تجزیه و تحلیل تقاضا برای صنعت بیمه عمر که تماما ناشی از عدم قطعیت در این صنعت میباشد انجام داده اند .وهدف از آن پیدا کردن شرایطی است که تحت آن شرایط انتخاب یا کنار گذاشتن یک بیمه گزار به نفع و یا زیان شرکت بیمه ...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dentistry, tehran university of medical sciences

جلد ۱۰، شماره ۳، صفحات ۲۴۰-۷

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023