biomechanical effects of platform switching in two different implant systems: a three-dimensional finite element analysis.
نویسندگان
چکیده
the purpose of this study was to determine the influence of platform switching on stress distribution of two different implant systems using three-dimensional (3d) finite element models.six 3d finite element models were created to replicate two different implant systems with peri-implant bone tissue, in which six different implant-abutment configurations were represented: model xive-a: 3.8-mm-diameter implant and 3.8-mm-diameter abutment; model xive-b (platform-switching model): 4.5-mm-diameter implant and 3.8-mm-diameter abutment; model xive-c: 4.5-mm-diameter implant and 4.5-mm-diameter abutment; model 3i-a: 4.0-mm-diameter implant and 4.1-mm-diameter abutment; model 3i-b (platform-switching model): 5.0-mm-diameter implant and 4.1-mm-diameter abutment; model 3i-c: 5.0-mm-diameter implant and 5.0-mm-diameter abutment. vertical and oblique loads of 100 were applied to all models.while the pattern of stress distribution was similar for both loading situations, oblique loading resulted in higher intensity and greater distribution of stress than axial loading in both cortical bone and implant-abutment- interface. stress distribution at peri-implant bone was almost identical with similar magnitudes for all six models. in both implant systems, platform-switching models demonstrated lower maximum von mises stress in cortical bone than conventional models. however, in both implant systems and under both loading situations, platform-switching models showed higher stresses at the implant-abutment interface than conventional models.in both implant systems, platform switching design reduced the stress concentration in the crestal bone and shifted it towards the area of implant-abutment interface.
منابع مشابه
Biomechanical Effects of Platform Switching in Two Different Implant Systems: A Three-Dimensional Finite Element Analysis
OBJECTIVES The purpose of this study was to determine the influence of platform switching on stress distribution of two different implant systems using three-dimensional (3D) finite element models. MATERIALS AND METHODS Six 3D finite element models were created to replicate two different implant systems with peri-implant bone tissue, in which six different implant-abutment configurations were...
متن کاملThree-dimensional finite element analysis of platform switched implant
PURPOSE The purpose of this study was to analyze the influence of the platform switching concept on an implant system and peri-implant bone using three-dimensional finite element analysis. MATERIALS AND METHODS Two three-dimensional finite element models for wide platform and platform switching were created. In the wide platform model, a wide platform abutment was connected to a wide platform...
متن کاملcomparison of bone biomechanical behavior around three different mini-implant systems employing finite element method
statement of problem: placement of mini-dental implants when single-tooth restorations are needed and the space is not sufficient to insert a standard diameter implant is indicated. there are many different mini-implant brands with various materials and surface characteristics; however, there are just few studies comparing them with each other. objectives: in this study, finite element analysis...
متن کاملBiomechanical Analysis of a Three Dimensional Finite Element Model
Low back pain has for long been associated with the lumbar spine biomechanics. A three dimensional model of segments L2 to L5 of lumbar spine is generated form CT images of a healthy human male. Hounsfield units of the image slices are used to derive material properties throughout the 3D model. This model is subjected to finite element analysis to study stresses developed during naturally found...
متن کامل[A three-dimensional finite element analysis for the biomechanical characteristics of orthodontic anchorage micro-implant].
PURPOSE To establish a three-dimensional finite element model for orthodontic anchorage micro-implant,and to analyze the influence of different titled angles on the biomechanical characteristics of orthodontic anchorage implant-bone interface. METHODS ANSYS(Analysis System)finite element analysis software was used to perform the finite element modeling of the micro-implant with 7 different ti...
متن کاملInfluence of three different implant thread designs on stress distribution: A three-dimensional finite element analysis
PURPOSE Clinical success of implant prosthodontics is dependent in part upon the type of implant thread design. The selection of implant thread design plays an important role in the outcome of the treatment. This study was undertaken to evaluate the pattern of stress distribution using a finite element analysis; hence, the area which would be bearing maximum load for a given design would be arr...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of dentistry, tehran university of medical sciencesجلد ۱۰، شماره ۴، صفحات ۳۳۸-۵۰
میزبانی شده توسط پلتفرم ابری doprax.com