the effect of implant length and diameter on the primary stability in different bone types.

نویسندگان

hamidreza barikani dental implant research center, tehran university of medical sciences tehran, iran.

shadab rashtak dental implant research center, tehran university of medical sciences tehran, iran.

soolmaz akbari dental implant research center, tehran university of medical sciences tehran, iran.

samareh badri dental implant research center, tehran university of medical sciences tehran, iran.

چکیده

the focus of this paper is to evaluate the influence of mechanical characteristics of the implant on primary stability in different bone types, based on resonance frequency analysis (rfa).a number of 60 nobel biocare replace select tiunit tapered implants of two different lengths (10 mm and 13 mm) and three different widths as 3.4 mm (narrow platform (np)), 4.3 mm (regular platform (rp)) and 5 mm (wide platform (wp)) were placed into two different groups of bone blocks. bone blocks were different in bone quality, but similar to bone types d1 and d3. immediately, after implant placement, implant stability quotient (isq) was measured using the osstell mentor device.isq values for implant placements in d1 bone were significantly higher than those for implants placed in d3 bone. in d1 bone, the implant length did not make any significant difference in primary stability; however, in d3 bone, the primary stability of the implant increased when longer implants were utilized. np implants presented significantly lower isq values compared to the two wider implants.in cases of low bone quality, the optimum increase in the implant length and diameter should be taken into account to achieve higher primary stability.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Implant Length and Diameter on the Primary Stability in Different Bone Types

OBJECTIVE The focus of this paper is to evaluate the influence of mechanical characteristics of the implant on primary stability in different bone types, based on resonance frequency analysis (RFA). MATERIALS AND METHODS A number of 60 Nobel Biocare Replace Select TiUnit Tapered implants of two different lengths (10 mm and 13 mm) and three different widths as 3.4 mm (narrow platform (NP)), 4....

متن کامل

the effect of task cognitive complexity and time limit on the performance of the learners with different proficiency levels in second language writing skill

this study investigated the effects of manipulating the cognitive complexity of tasks along +/- few elements and the time limits on l2 learners writing performance. to conduct the study, 60 iranian efl learners with two levels of proficiency, low and high intermediate, were selected and assigned to three groups based on the time devoted to task completion. the participants performed both a simp...

15 صفحه اول

the washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests

در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است

15 صفحه اول

the effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)

cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...

the effect of e-64 on the developmental competence of sheep cocs during in vitro maturation

in the present study, the effect of e-64 at different concentrations (0.5, 1, 5 and 10 µm) added to (1) the ivm medium on oocyte nuclear maturation and developmental competence of ovine oocytes, and (2) to the ivc medium on embryonic development of ovine embryos were investigated.

the effect of oxytetracycline on serum calcium, phosphorus and magnesium in cattle

نتایج این مطالعه نشان می دهد که مقدار کلسیم (یونیزه و تام)، منیزیم و فسفر به طور معنی داری تغییر پیدا کرد به جزء مقدار کلسیم تام و منیزیم در روش داخل عضلانی که تغییر معنی داری نداشته است. بر اساس نتایج این مطالعه می توان نتیجه گیری کرد که اکسی تتراساکلین بر روی مقادیر سرمی کلسیم و منیزیم تأثیر می گذارد باید مقدار این کاتیون ها در بیماران، در هنگامی که اکسی تتراسایکلین استفاده می شود مورد توجه ق...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dentistry, tehran university of medical sciences

جلد ۱۰، شماره ۵، صفحات ۴۴۹-۵۵

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023