unilateral outer bow expanded cervical headgear force system: 3d analysis using finite element method

نویسندگان

allahyar geramy professor, dental research center dentistry research institute, department of orthodontics, tehran university of medical sciences, tehran, iran

omid mortezai assistant professor of orthodontics, dental caries prevention research center, qazvin university of medical sciences, qazvin, iran

masomeh esmaily assistant professor, department of orthodontics, lorestan university of medical sciences, khorramabad, iran

hojat darvishpour postgraduate student, orthodontics department, school of dentistry, tehran university of medical sciences, tehran, iran

چکیده

o bjectives: headgears are among the effective orthodontic appliances to achieve treatment goals. unilateral molar distal movement is sometimes needed during an orthodontic treat- ment, which can be achieved by an asymmetric headgear. different unilateral headgears have been introduced. the main goal of this study was to analyze the force system of uni- lateral expanded outer bow asymmetric headgears by the finite element method (fem). materials and methods : six 3d finite element models of a mesiodistal slice of the maxilla containing upper first molars, their periodontal ligaments (pdls), cancellous bone, cortical bone, and a cervical headgear with expanded outer bow attached to maxillary first molars were designed in solidworks 2010 and meshed in ansys workbench ver. 12.1. the mod- els were the same except for the degree of outer bow expansion. the outer bow ends were loaded with 2-newton force. the distal driving force and the net moment were evaluated. results : a decrease in the distalizing force in the normal side molar from 1.69 n to 1.37 n was shown by increasing the degree of unilateral expansion. at the same time, the force increased from 2.19 n to 2.49 n in the expanded side molar. a net moment increasing from 2.26 n.mm to 4.64 n.mm was also shown. conclusion : unilateral outer bow expansion can produce different distalizing forces in mo- lars, which increase by increasing the expansion.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unilateral Outer Bow Expanded Cervical Headgear Force System: 3D Analysis Using Finite Element Method

OBJECTIVES Headgears are among the effective orthodontic appliances to achieve treatment goals. Unilateral molar distal movement is sometimes needed during an orthodontic treatment, which can be achieved by an asymmetric headgear. Different unilateral headgears have been introduced. The main goal of this study was to analyze the force system of unilateral expanded outer bow asymmetric headgears...

متن کامل

asymmetric outer bow length and cervical headgear force system: 3d analysis using finite element method

o bjectives: this study sought to assess distal and lateral forces and moments of asymmetric headgears by variable outer bow lengths. materials and methods : four 3d finite element method (fem) models of a cer- vical headgear attached to the maxillary first molars were designed in solidworks2010 software and transferred to ansys workbench ver. 11 software. modelscontained the first molars, thei...

متن کامل

Asymmetric Outer Bow Length and Cervical Headgear Force System: 3D Analysis Using Finite Element Method

OBJECTIVES This study sought to assess distal and lateral forces and moments of asymmetric headgears by variable outer bow lengths. MATERIALS AND METHODS Four 3D finite element method (FEM) models of a cervical headgear attached to the maxillary first molars were designed in SolidWorks 2010 software and transferred to ANSYS Workbench ver. 11 software. Models contained the first molars, their ...

متن کامل

Asymmetric Head Gear: A Comparison between Unilateral Outer Bow Expansion and Unilateral Outer Bow Shortening - an Energy Approach using the Finite Element Method.

OBJECTIVE To compare the influence of outer bow length difference and unilateral outer bow expansion on the 'asymmetric effect' of the headgear. METHODS Twelve 3D finite element models of a headgear with two tubes were designed, which were similar except for the outer bow length or the degree of unilateral expansion in Solid-Works 2011. A 3N force was applied to the outer bow ends in ANSYS Wo...

متن کامل

مقایسه وضعیت دندان‌های مولر فک بالا در کاربرد Cervical Headgear و دستگاه Pendulum (مطالعه Finite Element)

سابقه و هدف: رفتار بیومکانیکی مولرهای اول و دوم فک بالا، در مطالعات مختلف بالینی توسط هدگیر مورد بررسی قرار گرفته ولی در بعضی از ابعاد فضائی تناقض‌هایی وجود دارد. هدف از این مطالعه مقایسه وضعیت دندانهای مولر اول و دوم فک بالا در کاربردCervical headgear (HG) و (PEND ) دستگاه پندولوم از طریق Finite Element Method بود. مواد و روشها: جهت مدل‌سازی رایانه‌ای از یکی از کاملترین جمجمه‌های خشک، C.T. Sca...

متن کامل

fixed versus removable appliance for palatal expansion; a 3d analysis using the finite element method.

several appliances have been used for palatal expansion for treatment of posterior cross bite. the purpose of this study was to evaluate the stress induced in the apical and crestal alveolar bone and the pattern of tooth displacement following expansion via removable expansion plates or fixed-banded palatal expander using the finite element method (fem) analysis.two 3d fem models were designed ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dentistry, tehran university of medical sciences

جلد ۱۲، شماره ۴، صفحات ۲۷۱-۲۸۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023