accuracy of implant position transfer and surface detail reproduction with different impression materials and techniques
نویسندگان
چکیده
objectives: the purpose of this study was to compare the accuracy of implant position transfer and surface detail reproduction using two impression techniques and materials. materials and methods: a metal model with two implants and three grooves of 0.25, 0.50 and 0.75 mm in depth on the flat superior surface of a die was fabricated. ten regular-body polyether (pe) and 10 regular-body polyvinyl siloxane (pvs) impressions with square and conical transfer copings using open tray and closed tray techniques were made for each group. impressions were poured with type iv stone, and linear and angular displacements of the replica heads were evaluated using a coordinate measuring machine (cmm). also, accurate reproduction of the grooves was evaluated by a video measuring machine (vmm). these measurements were compared with the measurements calculated on the reference model that served as control, and the data were analyzed with two-way anova and t-test at p= 0.05. results: there was less linear displacement for pvs and less angular displacement for pe in closed-tray technique, and less linear displacement for pe in open tray technique (p<0.001). also, the open tray technique showed less angular displacement with the use of pvs impression material. detail reproduction accuracy was the same in all the groups (p>0.05(. conclusion: the open tray technique was more accurate using pe, and also both closed tray and open tray techniques had acceptable results with the use of pvs. the choice of impression material and technique made no significant difference in surface detail reproduction.
منابع مشابه
Accuracy of Implant Position Transfer and Surface Detail Reproduction with Different Impression Materials and Techniques
OBJECTIVES The purpose of this study was to compare the accuracy of implant position transfer and surface detail reproduction using two impression techniques and materials. MATERIALS AND METHODS A metal model with two implants and three grooves of 0.25, 0.50 and 0.75 mm in depth on the flat superior surface of a die was fabricated. Ten regular-body polyether (PE) and 10 regular-body polyvinyl...
متن کاملAccuracy of the implant impression obtained from different impression materials and techniques: review
With the predictable integration of implants, the emphasis is shifted towards precise prosthesis. Reproducing the intraoral relationship of implants through impression procedures is the first step in achieving an accurate, passively fitting prosthesis. The critical aspect is to record the three dimensional orientation of the implant as it is present intraorally, other than reproducing fine surf...
متن کاملeffect of different impression materials and techniques on the dimensional accuracy of implant defi nitive casts
background: different factors such as impression techniques and materials can affect the passive fi t between the superstructure and implant. the aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant defi nitive casts. materials and methods: four internal hex implants (biohorizons ø4 mm) were placed on a metal maxil...
متن کاملEffect of different impression materials and techniques on the dimensional accuracy of implant definitive casts
BACKGROUND Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. MATERIALS AND METHODS Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxilla...
متن کاملSurface detail reproduction and dimensional accuracy of stone models: influence of disinfectant solutions and alginate impression materials.
This study compared the surface detail reproduction and dimensional accuracy of stone models obtained from molds disinfected with 2% sodium hypochlorite, 2% chlorhexidine digluconate or 0.2% peracetic acid to models produced using molds which were not disinfected, with 3 alginate materials (Cavex ColorChange, Hydrogum 5 and Jeltrate Plus). The molds were prepared over matrix containing 20-, 50-...
متن کاملDimensional Accuracy of Polyvinyl Siloxane Impression Materials Considering Impression Techniques– A Literature Review
Objectives Impression accuracy is the main determinant of the fit, form and function of prosthetic restorations. Polyvinyl siloxane (PVS) is the material of choice in most clinical situations. The purpose of this paper is to provide an up-to-date review of scientific articles which discuss the dimensional accuracy of PVS impression material using various impression techniques, tray types and sp...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of dentistry, tehran university of medical sciencesجلد ۱۲، شماره ۱۰، صفحات ۷۷۴-۷۸۳
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023