objectives: this study sought to assess the effects of length and inclination of implants on stress distribution in an implant and terminal abutment teeth in an implant assisted-removable partial denture (rpd) using three-dimensional (3d) finite element analysis (fea).   materials and methods: in this in vitro study, a 3d finite element model of a partially dentate mandible with a distal extension rpd (derpd) and dental implants was designed to analyze stress distribution in bone around terminal abutment teeth (first premolar) and implants with different lengths (7 and 10 mm) and angles (0°, 10° and 15°). results: stress in the periodontal ligament (pdl) of the first premolar teeth ranged between 0.133 mpa in 10mm implants with 15° angle and 0.248 mpa in 7mm implants with 0° angle. the minimum stress was noted in implants with 10mm length with 0° angle (19.33 mpa) while maximum stress (25.78 mpa) was found in implants with 10mm length and 15° angle. in implants with 7 mm length, with an increase in implant angle, the stress on implants gradually increased. in implants with 10 mm length, increasing the implant angle gradually increased the stress on implants. conclusion: not only the length of implant but also the angle of implantation are important to minimize stress on implants. the results showed that vertical implant placement results in lower stress on implants and by increasing the angle, distribution of stress gradually increases.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Length and Inclination of Implants on Terminal Abutment Teeth and Implants in Mandibular CL1 Removable Partial Denture Assessed by Three-Dimensional Finite Element Analysis

OBJECTIVES This study sought to assess the effects of length and inclination of implants on stress distribution in an implant and terminal abutment teeth in an implant assisted-removable partial denture (RPD) using three-dimensional (3D) finite element analysis (FEA). MATERIALS AND METHODS In this in vitro study, a 3D finite element model of a partially dentate mandible with a distal extensio...

متن کامل

Removable partial denture on osseointegrated implants and natural teeth.

Implants have been designed to provide edentulous patients with fixed prostheses or overdentures. Recently, implant-supported fixed partial prostheses and single crowns have become successful treatment alternatives to removable and fixed partial dentures. However, few researchers have examined "removable partial dentures on implants and natural teeth". In this article, we report two patients fi...

متن کامل

The influence of removable partial dentures on the periodontal health of abutment and non-abutment teeth

Background and Aims: Removable partial denture (RPDs) is a common therapy for rehabilitation of partialy edentulous patients while RPD causes a lot of periodontal problems. The purpose of this study was to investigate the effect of RPDs made in Babol dental school on the periodontal health of abutment and non-abutment teeth. Materials and Methods: In this cross sectional study, 70 patients who...

متن کامل

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

A Three-dimensional Finite Element Analysis of Mandibular Overdenture Supported by Cylindrical and Conical Implants

This 3D finite element study assessed the stress distribution in mandibular overdenture supported by the 3i Locator system attached to two cylindrical or conical implants placed at the canine region. A 100 N vertical load was applied over the right first molar of the two overdenture models. The von Mises stresses were concentrated at the cervical and middle implant thirds. Cylindrical implants ...

متن کامل

Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis

This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...