effect of voxel size and object location in the field of view on detection of bone defects in cone beam computed tomography

نویسندگان

hoorieh bashizadeh fakhar

mysa mallahi

mehrdad panjnoush

pooneh mohseni kashani

چکیده

objectives: this study aimed to assess the effect of voxel size and object location in the field of view (fov) on diagnostic accuracy of cone beam computed tomography (cbct) for detection of simulated bone defects. materials and methods: in this in vitro study, bone defects were drilled in four sections of a dry human mandible. bone blocks were fixed on a platform parallel to the horizontal plane and cbct images were acquired using 0.2mm and 0.3mm resolutions and five locations of fov (anterior, posterior, left, right and center). three reviewers viewed the images twice and the presence or absence of simulated bone defects was determined in positive and negative cases. results: sensitivity in different locations of fov ranged between 0.25-1.0 and 0.75-1.0 in low and high resolutions, respectively. these values were 0.625-1.0 and 0.69-1.0, respectively for specificity. intra-observer agreements were in the range of 0.84-1.0 and 0.75-1.0 and inter-observer agreements were in the range of 0.3-0.61 and 0.46-0.69 in high and low resolutions, respectively. the highest sensitivity was seen at the center of the fov and with an increase in resolution from 0.3mm to 0.2mm, the sensitivity increased specially in the posterior region of the fov while image resolutions and fov locations did not affect specificity. conclusions: the highest sensitivity values were obtained at the center of the fov and lowest values were seen in images acquired in the posterior region in low resolution. diagnostic accuracy improved with increased resolution. keywords: bone and bones; sensitivity and specificity; cone-beam computed tomography

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Voxel Size and Object Location in the Field of View on Detection of Bone Defects in Cone Beam Computed Tomography

OBJECTIVES This study aimed to assess the effect of voxel size and object location in the field of view (FOV) on diagnostic accuracy of cone beam computed tomography (CBCT) for detection of simulated bone defects. MATERIALS AND METHODS In this in vitro study, bone defects were drilled in four sections of a dry human mandible. Bone blocks were fixed on a platform parallel to the horizontal pla...

متن کامل

effect of voxel size on detection of external root resorption defects using cone beam computed tomography

conclusion considering the similar diagnostic efficacy of all voxel sizes, 300 µm voxel size can be used with adequate efficacy for detection of external root resorption defects with minimal patient radiation dose and the shortest scanning time. background selecting a voxel size that yields minimal radiation dose with no significant compromise of the diagnostic accuracy of cone beam computed to...

متن کامل

Effect of Voxel Size on Detection of External Root Resorption Defects Using Cone Beam Computed Tomography

BACKGROUND Selecting a voxel size that yields minimal radiation dose with no significant compromise of the diagnostic accuracy of cone beam computed tomography (CBCT) is particularly important. OBJECTIVES This study aimed to assess the effect of voxel size on detection accuracy of simulated external root resorption defects using NewTom CBCT system. MATERIALS AND METHODS In this diagnostic s...

متن کامل

the washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests

در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است

15 صفحه اول

effect of field of view on detection of external root resorption in cone-beam computed tomography

introduction: conventional methods for diagnosis of external root resorption (err) are based on clinical findings and x-ray observations which are not appropriate for early diagnosis. the present study assessed the effect of different sizes and field of views (fovs) in the diagnosis of simulated external root resorption by cone-beam computed tomography (cbct). methods and materials: in this dia...

متن کامل

the effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)

cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dentistry, tehran university of medical sciences

جلد ۱۳، شماره ۴، صفحات ۲۷۹-۲۸۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023